2014Heilongjiang Electric PowerRequires access

Analysis of induced draft fan stall of 600MW unit

Liu Shanb

Open publisher page 0 citations

Abstract

Aiming at the large vibration of induced draft fan of the 600 MW unit in a thermal power plant,this paper expounds the mechanism and causes of stall of axial flow fan with adjustable static blades,measures the static pressure of the entrance and the exit of induced draft fan under different working condition,and compares the change of system resistance in the original and the temporary flue gas system,and proposes relevant transformation measures. The result shows that the increase of system resistance in temporary tail flue gas system will lead to fan stall and large vibration. The improved induced draft fan system guarantees the normal operation of fan and reduces the system resistance.

About this research paper

What this paper is about

Aiming at the large vibration of induced draft fan of the 600 MW unit in a thermal power plant,this paper expounds the mechanism and causes of stall of axial flow fan with adjustable static blades,measures the static pressure of the entrance and the exit of induced draft fan under different working condition,and compares the change of system resistance in the original and the temporary flue gas system,and proposes relevant transformation measures. The result shows that the increase of system resistance in temporary tail flue gas system will lead to fan stall and large vibration. The improved induced draft fan system guarantees the normal operation of fan and reduces the system resistance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aiming at the large vibration of induced draft fan of the 600 MW unit in a thermal power plant,this paper expounds the mechanism and causes of stall of axial flow fan with adjustable static blades,measures the static pressure of the entrance and the exit of induced draft fan under different working condition,and compares the change of system resistance in the original and the temporary flue gas system,and proposes relevant transformation measures. The result shows that the increase of system resistance in temporary tail flue gas system will lead to fan stall and large vibration. The improved induced draft fan system guarantees the normal operation of fan and reduces the system resistance.

Key concepts: Stall (fluid mechanics), Hull, Engineering, Flue gas, Mechanical fan, Fan-in, Vibration, Static pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of induced draft fan stall of 600MW unit — Research Paper | ScholarLens