2011Shaanxi Electric PowerRequires access

Partial Discharge of GIS Insulation Void Models under Oscillating Impulse Voltage

Yanming Li

Open publisher page 0 citations

Abstract

For more comprehensive detection of GIS equipment on-site test,the impulse voltage test should be increased in the onsite acceptance test of GIS equipment based on the relevant rules.Oscillating impulse voltage waveform generator is designed complying with the provisions of IEC 60060-3,and the insulation defect models of different void dimension are made,and a partial discharge pulse measurement system under impulse voltage is set up.The paper studies the partial discharge properties of GIS insulation void defect under the impulse voltage,especially under the oscillating impulse voltage,compares the different characteristics of the partial discharge under different voltages,and analyzes the PD mechanism and process of the insulation void model under impulse voltage.It can be used as guidance for the high voltage GIS on-site testing under the oscillating impulse.

About this research paper

What this paper is about

For more comprehensive detection of GIS equipment on-site test,the impulse voltage test should be increased in the onsite acceptance test of GIS equipment based on the relevant rules.Oscillating impulse voltage waveform generator is designed complying with the provisions of IEC 60060-3,and the insulation defect models of different void dimension are made,and a partial discharge pulse measurement system under impulse voltage is set up.The paper studies the partial discharge properties of GIS insulation void defect under the impulse voltage,especially under the oscillating impulse voltage,compares the different characteristics of the partial discharge under different voltages,and analyzes the PD mechanism and process of the insulation void model under impulse voltage.It can be used as guidance for the high voltage GIS on-site testing under the oscillating impulse.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For more comprehensive detection of GIS equipment on-site test,the impulse voltage test should be increased in the onsite acceptance test of GIS equipment based on the relevant rules.Oscillating impulse voltage waveform generator is designed complying with the provisions of IEC 60060-3,and the insulation defect models of different void dimension are made,and a partial discharge pulse measurement system under impulse voltage is set up.The paper studies the partial discharge properties of GIS insulation void defect under the impulse voltage,especially under the oscillating impulse voltage,compares the different characteristics of the partial discharge under different voltages,and analyzes the PD mechanism and process of the insulation void model under impulse voltage.It can be used as guidance for the high voltage GIS on-site testing under the oscillating impulse.

Key concepts: Partial discharge, Impulse (physics), Impulse generator, Voltage, Waveform, Void (composites), High voltage, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Partial Discharge of GIS Insulation Void Models under Oscillating Impulse Voltage — Research Paper | ScholarLens