2008•Food ScienceRequires access

Inhibitory Kinetic Spectrophotometric Determination of Trace Iodinein in Food with Cationic Surfactant Sensitizer

Wang Xiao-ju

Open publisher page 0 citations

Abstract

An inhibitory kinetic spectrophotometric method was proposed for the determination of trace iodine. The method is based on the inhibition effect of iodine on the nitrite-catalyzed oxidation of menthylene blue by potassium bromate in dilute sulphuric acid medium. The linear range of the determination is 0 to 480 g/L,and the detection limit is 3.7×10-7 g/L. This method is simple,rapid and highly sensitive. It has been used for determination of trace iodine in salt with satisfactory results.

About this research paper

What this paper is about

An inhibitory kinetic spectrophotometric method was proposed for the determination of trace iodine. The method is based on the inhibition effect of iodine on the nitrite-catalyzed oxidation of menthylene blue by potassium bromate in dilute sulphuric acid medium. The linear range of the determination is 0 to 480 g/L,and the detection limit is 3.7×10-7 g/L. This method is simple,rapid and highly sensitive. It has been used for determination of trace iodine in salt with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An inhibitory kinetic spectrophotometric method was proposed for the determination of trace iodine. The method is based on the inhibition effect of iodine on the nitrite-catalyzed oxidation of menthylene blue by potassium bromate in dilute sulphuric acid medium. The linear range of the determination is 0 to 480 g/L,and the detection limit is 3.7×10-7 g/L. This method is simple,rapid and highly sensitive. It has been used for determination of trace iodine in salt with satisfactory results.

Key concepts: Potassium bromate, Iodine, Chemistry, Detection limit, Cationic polymerization, Bromate, Pulmonary surfactant, Nitrite

Related papers

Back to paper searchBrowse research topicsOriginal source
Inhibitory Kinetic Spectrophotometric Determination of Trace Iodinein in Food with Cationic Surfactant Sensitizer — Research Paper | ScholarLens