2004•Metallurgical AnalysisRequires access

Determination of trace amounts of iodine by inhibition kinetic spectrophotometry

Jianwei Xue

Open publisher page 0 citations

Abstract

A simple and sensitive kinetic spetrophotometric method for determination of trace iodine has been developed.The method is based on the inhibition effect of iodine on the fading reaction in which nitrite catalyzes potassium bromate to oxidize methylene blue in dilute phosphoric acid medium.The linear range of determination is 0.040-0.48 μg/mL.The detection limit is 1.7×10~(-8) g/mL.The method has been used for the determination of trace iodine in salt sample with satisfactory results.

About this research paper

What this paper is about

A simple and sensitive kinetic spetrophotometric method for determination of trace iodine has been developed.The method is based on the inhibition effect of iodine on the fading reaction in which nitrite catalyzes potassium bromate to oxidize methylene blue in dilute phosphoric acid medium.The linear range of determination is 0.040-0.48 μg/mL.The detection limit is 1.7×10~(-8) g/mL.The method has been used for the determination of trace iodine in salt sample with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and sensitive kinetic spetrophotometric method for determination of trace iodine has been developed.The method is based on the inhibition effect of iodine on the fading reaction in which nitrite catalyzes potassium bromate to oxidize methylene blue in dilute phosphoric acid medium.The linear range of determination is 0.040-0.48 μg/mL.The detection limit is 1.7×10~(-8) g/mL.The method has been used for the determination of trace iodine in salt sample with satisfactory results.

Key concepts: Potassium bromate, Iodine, Chemistry, Detection limit, Spectrophotometry, Methylene blue, Trace Amounts, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace amounts of iodine by inhibition kinetic spectrophotometry — Research Paper | ScholarLens