2003Chinese Journal of PharmaceuticalsRequires access

Identification of Chidan Pills and Determination of Paeonflorin

Ying Xu

Open publisher page 0 citations

Abstract

A TLC method for identification of radix paeoniae rubra, radix salviae miltiorrhizae, radix scutellariae, poria and rhizoma sparganii in Chidan pills and a HPLC method for determination of paeonflorin in pills were presented. A Diamonsil C_ 18 column was used with the mobile phase of acetonitrile-water (20∶80), at room temperature and detection wavelength of 230 nm. The calibration curve of paeonflorin was linear in the concentration range of 16~160 μg/ml( r=0.9999) .The average recovery was 99.1% with RSD of 2.09%.

About this research paper

What this paper is about

A TLC method for identification of radix paeoniae rubra, radix salviae miltiorrhizae, radix scutellariae, poria and rhizoma sparganii in Chidan pills and a HPLC method for determination of paeonflorin in pills were presented. A Diamonsil C_ 18 column was used with the mobile phase of acetonitrile-water (20∶80), at room temperature and detection wavelength of 230 nm. The calibration curve of paeonflorin was linear in the concentration range of 16~160 μg/ml( r=0.9999) .The average recovery was 99.1% with RSD of 2.09%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A TLC method for identification of radix paeoniae rubra, radix salviae miltiorrhizae, radix scutellariae, poria and rhizoma sparganii in Chidan pills and a HPLC method for determination of paeonflorin in pills were presented. A Diamonsil C_ 18 column was used with the mobile phase of acetonitrile-water (20∶80), at room temperature and detection wavelength of 230 nm. The calibration curve of paeonflorin was linear in the concentration range of 16~160 μg/ml( r=0.9999) .The average recovery was 99.1% with RSD of 2.09%.

Key concepts: Chemistry, Radix (gastropod), Chromatography, Calibration curve, High-performance liquid chromatography, Pill, Detection limit, Pharmacology

Related papers

Back to paper searchBrowse research topicsOriginal source
Identification of Chidan Pills and Determination of Paeonflorin — Research Paper | ScholarLens