2012Metallurgical AnalysisRequires access

Determination of trace mercury in geochemical samples by atomic fluorescence spectrometry

Yuxue Wang

Open publisher page 0 citations

Abstract

The analysis method of mercury in geochemical exploration samples by hydride generation-atomic fluorescence spectrometry combined with polyethylene film closed ore dissolution in concussive water bath was proposed.Parameters,including ore dissolution method,lamp current,carrier gas,shielding gas flow and potassium borohydride concentration,were optimized.Under optimal conditions the calibration curve of mercury was established,the correlation coefficients were in range of 0.999 1-0.999 3,and the detection limit of mercury was 0.125 ng/g.The proposed method was applied to the analysis of standard and actual geochemical exploration samples,and the determination results were consistent with the certified values or those obtained by two-stage gold amalgamation cold vapor atomic absorption spectrometry after closed dissolution.The relative standard deviation(RSD,n=5) was less than 3.5 %.

About this research paper

What this paper is about

The analysis method of mercury in geochemical exploration samples by hydride generation-atomic fluorescence spectrometry combined with polyethylene film closed ore dissolution in concussive water bath was proposed.Parameters,including ore dissolution method,lamp current,carrier gas,shielding gas flow and potassium borohydride concentration,were optimized.Under optimal conditions the calibration curve of mercury was established,the correlation coefficients were in range of 0.999 1-0.999 3,and the detection limit of mercury was 0.125 ng/g.The proposed method was applied to the analysis of standard and actual geochemical exploration samples,and the determination results were consistent with the certified values or those obtained by two-stage gold amalgamation cold vapor atomic absorption spectrometry after closed dissolution.The relative standard deviation(RSD,n=5) was less than 3.5 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analysis method of mercury in geochemical exploration samples by hydride generation-atomic fluorescence spectrometry combined with polyethylene film closed ore dissolution in concussive water bath was proposed.Parameters,including ore dissolution method,lamp current,carrier gas,shielding gas flow and potassium borohydride concentration,were optimized.Under optimal conditions the calibration curve of mercury was established,the correlation coefficients were in range of 0.999 1-0.999 3,and the detection limit of mercury was 0.125 ng/g.The proposed method was applied to the analysis of standard and actual geochemical exploration samples,and the determination results were consistent with the certified values or those obtained by two-stage gold amalgamation cold vapor atomic absorption spectrometry after closed dissolution.The relative standard deviation(RSD,n=5) was less than 3.5 %.

Key concepts: Mercury (programming language), Cold vapour atomic fluorescence spectroscopy, Chemistry, Detection limit, Dissolution, Analytical Chemistry (journal), Atomic absorption spectroscopy, Calibration curve