2002•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Trace Element in Hair of Mental Patients by Microwave Oven High-pressure Digestion- Flame Atomic Absorption Spectrophotometry

Huang Sen

Open publisher page 0 citations

Abstract

A method of determining trace elements (Cu,Zn,Fe and Mn) by microwave oven high-pressure digestion-flame atomic absorption spectrophotometry was proposed. The detection limits of this method are 0.001μg/mL (Cu 2+,Zn 2+,Mn 2+) and 0.005μg/mL (Fe 3+). The response is linear over the range of 0.1-2.5μg/mL for Cu 2+and Zn 2+,0.1-1.0μg/mL for Mn 2+,0.1-5.0μg/mL for Fe 3+,respectively with a correlation coefficient of 0.9997-0.9999.This method has been successfully applied to the determination of Cu,Zn,Fe and Mn in hair.

About this research paper

What this paper is about

A method of determining trace elements (Cu,Zn,Fe and Mn) by microwave oven high-pressure digestion-flame atomic absorption spectrophotometry was proposed. The detection limits of this method are 0.001μg/mL (Cu 2+,Zn 2+,Mn 2+) and 0.005μg/mL (Fe 3+). The response is linear over the range of 0.1-2.5μg/mL for Cu 2+and Zn 2+,0.1-1.0μg/mL for Mn 2+,0.1-5.0μg/mL for Fe 3+,respectively with a correlation coefficient of 0.9997-0.9999.This method has been successfully applied to the determination of Cu,Zn,Fe and Mn in hair.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method of determining trace elements (Cu,Zn,Fe and Mn) by microwave oven high-pressure digestion-flame atomic absorption spectrophotometry was proposed. The detection limits of this method are 0.001μg/mL (Cu 2+,Zn 2+,Mn 2+) and 0.005μg/mL (Fe 3+). The response is linear over the range of 0.1-2.5μg/mL for Cu 2+and Zn 2+,0.1-1.0μg/mL for Mn 2+,0.1-5.0μg/mL for Fe 3+,respectively with a correlation coefficient of 0.9997-0.9999.This method has been successfully applied to the determination of Cu,Zn,Fe and Mn in hair.

Key concepts: Atomic absorption spectroscopy, Microwave oven, Microwave digestion, Analytical Chemistry (journal), Detection limit, Chemistry, Spectrophotometry, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Element in Hair of Mental Patients by Microwave Oven High-pressure Digestion- Flame Atomic Absorption Spectrophotometry — Research Paper | ScholarLens