2009CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (CHINESE VERSION)Requires access

Flow Injection Post-Chemiluminescence Analysis of Amikacin

Yan Rui

Open publisher page 3 citations

Abstract

In basic medium of pH=11.5,peroxymonosulfate(PMS),a strong oxidant,can oxidize the luminol to produce chemiluminescence,and after the injection of amikacin,the luminescence rate becomes slow and strong post-chemiluminescence(PCL).Based on this,a new CL method was developed for the determination of amikacin using flow injection chemiluminescence analysis.A possible mechanism for the CL was discussed via the studies of kinetic characteristics,the CL spectra and UV spectrum.The linear range was 4.0×10-5-8.0×10-2 g/L with a detection limit of 1×10-5 g/L for amikacin and the relative standard deviation was 2.9%(c=4.0×10-6 g/mL,n=11).The proposed method was selective,simple,rapid and reproducible,and has been successfully applied to the analysis of human urine samples with satisfactory results.

About this research paper

What this paper is about

In basic medium of pH=11.5,peroxymonosulfate(PMS),a strong oxidant,can oxidize the luminol to produce chemiluminescence,and after the injection of amikacin,the luminescence rate becomes slow and strong post-chemiluminescence(PCL).Based on this,a new CL method was developed for the determination of amikacin using flow injection chemiluminescence analysis.A possible mechanism for the CL was discussed via the studies of kinetic characteristics,the CL spectra and UV spectrum.The linear range was 4.0×10-5-8.0×10-2 g/L with a detection limit of 1×10-5 g/L for amikacin and the relative standard deviation was 2.9%(c=4.0×10-6 g/mL,n=11).The proposed method was selective,simple,rapid and reproducible,and has been successfully applied to the analysis of human urine samples with satisfactory results.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In basic medium of pH=11.5,peroxymonosulfate(PMS),a strong oxidant,can oxidize the luminol to produce chemiluminescence,and after the injection of amikacin,the luminescence rate becomes slow and strong post-chemiluminescence(PCL).Based on this,a new CL method was developed for the determination of amikacin using flow injection chemiluminescence analysis.A possible mechanism for the CL was discussed via the studies of kinetic characteristics,the CL spectra and UV spectrum.The linear range was 4.0×10-5-8.0×10-2 g/L with a detection limit of 1×10-5 g/L for amikacin and the relative standard deviation was 2.9%(c=4.0×10-6 g/mL,n=11).The proposed method was selective,simple,rapid and reproducible,and has been successfully applied to the analysis of human urine samples with satisfactory results.

Key concepts: Chemiluminescence, Chemistry, Amikacin, Detection limit, Flow injection analysis, Luminol, Relative standard deviation, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow Injection Post-Chemiluminescence Analysis of Amikacin — Research Paper | ScholarLens