A novel luminol-based chemiluminescence method for the determination of amikacin sulfate in serum by using trivalent copper-periodate complex
Yufei Hu, Gongke Li, Zhujun Zhang
Abstract
Open-access reader
Yufei Hu, Gongke Li, Zhujun Zhang
Abstract
Open-access reader
A novel chemiluminescence (CL) reaction was based on the oxidizing reaction of luminol by the trivalent copper-periodate complex (K5[Cu(HIO6)2], DPC) in alkaline medium. The CL intensity could be enhanced in the presence of amikacin sulfate (AKS). A new CL method was developed for the determination of AKS by coupling with flow injection (FI) technology. Because of the distinctive oxidative effect of DPC, the luminol-based CL reaction could occur at a low concentration of 10−7 M. The relative CL intensity was proportional to the concentration of AKS in the range of 4.0×10−9–4.0×10−6 g/mL with the detection limit of 1.2×10−9 g/mL. The relative standard deviation was 2.1% for 8.0×10−9 g/mL AKS (n=9). The proposed method was successfully applied to the direct determination of AKS at the level of ng/mL in serum samples. The recovery varied from 97.0% to 106.3%. A possible mechanism of the CL reaction was discussed in detail by relating to the CL kinetic characteristics and electrochemical activities of the oxidant DPC.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel chemiluminescence (CL) reaction was based on the oxidizing reaction of luminol by the trivalent copper-periodate complex (K5[Cu(HIO6)2], DPC) in alkaline medium. The CL intensity could be enhanced in the presence of amikacin sulfate (AKS). A new CL method was developed for the determination of AKS by coupling with flow injection (FI) technology. Because of the distinctive oxidative effect of DPC, the luminol-based CL reaction could occur at a low concentration of 10−7 M. The relative CL intensity was proportional to the concentration of AKS in the range of 4.0×10−9–4.0×10−6 g/mL with the detection limit of 1.2×10−9 g/mL. The relative standard deviation was 2.1% for 8.0×10−9 g/mL AKS (n=9). The proposed method was successfully applied to the direct determination of AKS at the level of ng/mL in serum samples. The recovery varied from 97.0% to 106.3%. A possible mechanism of the CL reaction was discussed in detail by relating to the CL kinetic characteristics and electrochemical activities of the oxidant DPC.
Key concepts: Chemistry, Chemiluminescence, Luminol, Periodate, Detection limit, Relative standard deviation, Copper, Oxidizing agent