2010Chinese Journal of ChromatographyRequires access

Determination of decoquinate in chicken meat by high performance liquid chromatography-tandem mass spectrometry

Chen Rui-qing, Yu DaoJin, Chen Feng, Yifan Huang

Open publisher page 2 citations

Abstract

A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of decoquinate (DEC) residue in chicken meat. The sample was extracted with acetonitrile,cleaned-up with hexane,and purified with solid phase extraction (SPE) cartridge. The mobile phase was acetonitrile (containing 0.1% formic acid) and water (containing 0.1% formic acid). The analyte was identified by positive electrospray ionization (ESI+) mode and multiple reaction monitoring (MRM) mode. The results showed as follows:The calibration curve showed good linearity within the concentrations of 1-200 μg/L with the correlation coefficient (r2)0.99. At the spiked levels of 1,10 and 100 μg/kg,the recoveries of DEC were 78.2%-107.4%. The relative standard deviations (RSDs) of intra-and inter-days were both less than 15%. The limit of detection of DEC was 0.25 μg/kg and the limit of quantification was 0.5 μg/kg. The method is simple,sensitive and accurate in the determination of DEC residue,which can meet the requirements of the domestic and international legislations.

About this research paper

What this paper is about

A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of decoquinate (DEC) residue in chicken meat. The sample was extracted with acetonitrile,cleaned-up with hexane,and purified with solid phase extraction (SPE) cartridge. The mobile phase was acetonitrile (containing 0.1% formic acid) and water (containing 0.1% formic acid). The analyte was identified by positive electrospray ionization (ESI+) mode and multiple reaction monitoring (MRM) mode. The results showed as follows:The calibration curve showed good linearity within the concentrations of 1-200 μg/L with the correlation coefficient (r2)0.99. At the spiked levels of 1,10 and 100 μg/kg,the recoveries of DEC were 78.2%-107.4%. The relative standard deviations (RSDs) of intra-and inter-days were both less than 15%. The limit of detection of DEC was 0.25 μg/kg and the limit of quantification was 0.5 μg/kg. The method is simple,sensitive and accurate in the determination of DEC residue,which can meet the requirements of the domestic and international legislations.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of decoquinate (DEC) residue in chicken meat. The sample was extracted with acetonitrile,cleaned-up with hexane,and purified with solid phase extraction (SPE) cartridge. The mobile phase was acetonitrile (containing 0.1% formic acid) and water (containing 0.1% formic acid). The analyte was identified by positive electrospray ionization (ESI+) mode and multiple reaction monitoring (MRM) mode. The results showed as follows:The calibration curve showed good linearity within the concentrations of 1-200 μg/L with the correlation coefficient (r2)0.99. At the spiked levels of 1,10 and 100 μg/kg,the recoveries of DEC were 78.2%-107.4%. The relative standard deviations (RSDs) of intra-and inter-days were both less than 15%. The limit of detection of DEC was 0.25 μg/kg and the limit of quantification was 0.5 μg/kg. The method is simple,sensitive and accurate in the determination of DEC residue,which can meet the requirements of the domestic and international legislations.

Key concepts: Chemistry, Chromatography, Formic acid, Detection limit, Residue (chemistry), Selected reaction monitoring, Mass spectrometry, Electrospray ionization

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of decoquinate in chicken meat by high performance liquid chromatography-tandem mass spectrometry — Research Paper | ScholarLens