2010Guangdong nongye kexueOpen access

Rapid determination of Chloramphenicol residue in fish by Highperformance Liquid Chromatographic Method-Tandem Mass Spectrometry

Guangjie Wu

Open full text 0 citations

Abstract

An High-performance liquid chromatographic method with tandem mass spectrometry (HPLC-MS/MS) was developed for the determination of Chloramphenicol (CAP) residue in fish.The CAP residue was extracted by ethyl acetate.Concentrated extracts were redissolved in 1 mL dissolving solution and defatted by hexane.The solution was separated on a RP -HPLC column and detected by HPLC-MS/MS with positive electrospray ionization(ESI-) in multiple reaction monitoring(MRM) mode.Quantitation was carried out using an external standard method.The standard curve for CAP was linear over the concentration range of 0.04 ~1.0 μg/kg with correlation coefficients (R2) of 0.9999. The recoveries of CAP from fish samples spiked with the concentration levels at 0.10, 0.20, 0.40 μg/kg were range of 91.0%~100.1%. The relative standard deviations were 2.6%~4.1%. The limit of detection for the method was 0.01 μg/kg. The limit of quantification for the method was 0.02 μg/kg.

About this research paper

What this paper is about

An High-performance liquid chromatographic method with tandem mass spectrometry (HPLC-MS/MS) was developed for the determination of Chloramphenicol (CAP) residue in fish.The CAP residue was extracted by ethyl acetate.Concentrated extracts were redissolved in 1 mL dissolving solution and defatted by hexane.The solution was separated on a RP -HPLC column and detected by HPLC-MS/MS with positive electrospray ionization(ESI-) in multiple reaction monitoring(MRM) mode.Quantitation was carried out using an external standard method.The standard curve for CAP was linear over the concentration range of 0.04 ~1.0 μg/kg with correlation coefficients (R2) of 0.9999. The recoveries of CAP from fish samples spiked with the concentration levels at 0.10, 0.20, 0.40 μg/kg were range of 91.0%~100.1%. The relative standard deviations were 2.6%~4.1%. The limit of detection for the method was 0.01 μg/kg. The limit of quantification for the method was 0.02 μg/kg.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An High-performance liquid chromatographic method with tandem mass spectrometry (HPLC-MS/MS) was developed for the determination of Chloramphenicol (CAP) residue in fish.The CAP residue was extracted by ethyl acetate.Concentrated extracts were redissolved in 1 mL dissolving solution and defatted by hexane.The solution was separated on a RP -HPLC column and detected by HPLC-MS/MS with positive electrospray ionization(ESI-) in multiple reaction monitoring(MRM) mode.Quantitation was carried out using an external standard method.The standard curve for CAP was linear over the concentration range of 0.04 ~1.0 μg/kg with correlation coefficients (R2) of 0.9999. The recoveries of CAP from fish samples spiked with the concentration levels at 0.10, 0.20, 0.40 μg/kg were range of 91.0%~100.1%. The relative standard deviations were 2.6%~4.1%. The limit of detection for the method was 0.01 μg/kg. The limit of quantification for the method was 0.02 μg/kg.

Key concepts: Chromatography, Chemistry, Residue (chemistry), Tandem mass spectrometry, Detection limit, Selected reaction monitoring, Mass spectrometry, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid determination of Chloramphenicol residue in fish by Highperformance Liquid Chromatographic Method-Tandem Mass Spectrometry — Research Paper | ScholarLens