2010Chinese Journal of Health Laboratory TechnologyRequires access

Simultaneous determineation of arsenic and selenium in tea by atomic fluorescence spectrometry

Xiaoyu Guo

Open publisher page 0 citations

Abstract

Objective:A method for the simultaneous determineation of arsenic and selenium in the tea by atomic fluorescence spectrometry has been developed.Methods:The sample was dissolved with HNO3-HCLO7,and analyzed by AFS-9130 double-channel atomic fluorescence spectometor.Results:Under the best condition,the relation standard deviation of arsenic and selenium was 5.58% and 5.92%.The detection limit of the atsenic and selenium was 0.0020 mg/kg and 0.0038 mg/kg.The coveries of arsenic and selenium ranged form 91.0% to 99.1% and 95.0% to 98.3%.Conclusion:The above method is highly sensilive,repeatable and applicable.

About this research paper

What this paper is about

Objective:A method for the simultaneous determineation of arsenic and selenium in the tea by atomic fluorescence spectrometry has been developed.Methods:The sample was dissolved with HNO3-HCLO7,and analyzed by AFS-9130 double-channel atomic fluorescence spectometor.Results:Under the best condition,the relation standard deviation of arsenic and selenium was 5.58% and 5.92%.The detection limit of the atsenic and selenium was 0.0020 mg/kg and 0.0038 mg/kg.The coveries of arsenic and selenium ranged form 91.0% to 99.1% and 95.0% to 98.3%.Conclusion:The above method is highly sensilive,repeatable and applicable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:A method for the simultaneous determineation of arsenic and selenium in the tea by atomic fluorescence spectrometry has been developed.Methods:The sample was dissolved with HNO3-HCLO7,and analyzed by AFS-9130 double-channel atomic fluorescence spectometor.Results:Under the best condition,the relation standard deviation of arsenic and selenium was 5.58% and 5.92%.The detection limit of the atsenic and selenium was 0.0020 mg/kg and 0.0038 mg/kg.The coveries of arsenic and selenium ranged form 91.0% to 99.1% and 95.0% to 98.3%.Conclusion:The above method is highly sensilive,repeatable and applicable.

Key concepts: Selenium, Arsenic, Chemistry, Detection limit, Environmental chemistry, Fluorescence spectrometry, Relative standard deviation, Fluorescence

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determineation of arsenic and selenium in tea by atomic fluorescence spectrometry — Research Paper | ScholarLens