Simultaneous Determination of Arsenic and Selenium in Water by Atomic Fluorescence Spectrum
Jianwei Liu
Abstract
Jianwei Liu
Abstract
Objective To establish a method for simultaneously analyzing arsenic and selenium in water by atomic fluorescence spectrum.Methods Double-path atomic fluorescence spectrum was used to analyze arsenic and selenium in water simultaneously.Results The detection limits of arsenic and selenium with the method were 0.008 8 ng/ml and 0.02 ng/ml;The recovery rates were 95.5%-101.4% for arsenic and 94.5%~100.6% for selenium;relative standard deviations were 1.7%-4.2% for arsenic and 2.7%-7.8% for selenium.There was good correlation coefficient(0.999 8) of arsenic in concentration range of 1.0-10.0 ng/ml.There was good correlation coefficient(0.999 3) of selenium in concentration range of 2.0-20.0 ng/ml.There was no significant difference between the detection values obtained by this method and national standard method(GB/T 5750-2006)(P0.05).Conclusion The method both simplifies the operation process and reduces detection time.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a method for simultaneously analyzing arsenic and selenium in water by atomic fluorescence spectrum.Methods Double-path atomic fluorescence spectrum was used to analyze arsenic and selenium in water simultaneously.Results The detection limits of arsenic and selenium with the method were 0.008 8 ng/ml and 0.02 ng/ml;The recovery rates were 95.5%-101.4% for arsenic and 94.5%~100.6% for selenium;relative standard deviations were 1.7%-4.2% for arsenic and 2.7%-7.8% for selenium.There was good correlation coefficient(0.999 8) of arsenic in concentration range of 1.0-10.0 ng/ml.There was good correlation coefficient(0.999 3) of selenium in concentration range of 2.0-20.0 ng/ml.There was no significant difference between the detection values obtained by this method and national standard method(GB/T 5750-2006)(P0.05).Conclusion The method both simplifies the operation process and reduces detection time.
Key concepts: Arsenic, Selenium, Chemistry, Correlation coefficient, Analytical Chemistry (journal), Environmental chemistry, Mathematics, Organic chemistry