2007PubMedRequires access

[Determination of protocatechuic acid in rat plasma by high performance liquid chromatography].

Ying Han, Zhili Xiong, Chunjuan Yang, Man Liu, Famei Li

Open publisher page 3 citations

Abstract

A method was developed for the quantitative determination of protocatechuic acid in rat plasma by high performance liquid chromatography (HPLC). With added p-hydroxybenzoic acid as internal standard, the plasma samples were extracted with a solvent mixture of methanol and acetonitrile ( 1: 5, v/v). The analyte was determined by HPLC with a Diamondsil C18 column and a mobile phase of acetonitrile-water (adjusted to pH 2.5 with H3PO4, 9: 91, v/v) at a flow rate of 1. 2 mL/min. The UV detection wavelength was 260 nm. The assay exhibited a good linearity in the concentration range from 0. 050 to 3. 20 mg/L with a correlation coefficient of 0. 997 8. The limit of quantification was 0. 050 mg/L. The relative standard deviations of intra-day and inter-day determination were both less than 7. 0% and the accuracy ranged from - 1. 4% to 2. 6%. The extraction recoveries of protocatechuic acid from rat plasma samples at three concentration levels were 83. 4%, 87. 3%, and 91. 1%, respectively. The developed method was applied to a pharmacokinetic study. The main pharmacokinetic parameters in rats after a single oral dose of 10 mL/kg body weight were as follows: Cmax of (3. 16 +0. 03) microg/mL, tmax of (0. 50 +/- 0. 00) h, AU0-->t of (39. 9 +/- 5. 9) microg x mL(-1) x h, AUC-->infinity of (54. 8 +/- 8. 1) microg x mL(-1) x h and t1/2 of (3. 87 +/- 0. 25) h. The method was proved to be simple, sensitive and accurate, thus suitable for the pharmacokinetic study of protocatechuic acid in rat plasma.

About this research paper

What this paper is about

A method was developed for the quantitative determination of protocatechuic acid in rat plasma by high performance liquid chromatography (HPLC). With added p-hydroxybenzoic acid as internal standard, the plasma samples were extracted with a solvent mixture of methanol and acetonitrile ( 1: 5, v/v). The analyte was determined by HPLC with a Diamondsil C18 column and a mobile phase of acetonitrile-water (adjusted to pH 2.5 with H3PO4, 9: 91, v/v) at a flow rate of 1. 2 mL/min. The UV detection wavelength was 260 nm. The assay exhibited a good linearity in the concentration range from 0. 050 to 3. 20 mg/L with a correlation coefficient of 0. 997 8. The limit of quantification was 0. 050 mg/L. The relative standard deviations of intra-day and inter-day determination were both less than 7. 0% and the accuracy ranged from - 1. 4% to 2. 6%. The extraction recoveries of protocatechuic acid from rat plasma samples at three concentration levels were 83. 4%, 87. 3%, and 91. 1%, respectively. The developed method was applied to a pharmacokinetic study. The main pharmacokinetic parameters in rats after a single oral dose of 10 mL/kg body weight were as follows: Cmax of (3. 16 +0. 03) microg/mL, tmax of (0. 50 +/- 0. 00) h, AU0-->t of (39. 9 +/- 5. 9) microg x mL(-1) x h, AUC-->infinity of (54. 8 +/- 8. 1) microg x mL(-1) x h and t1/2 of (3. 87 +/- 0. 25) h. The method was proved to be simple, sensitive and accurate, thus suitable for the pharmacokinetic study of protocatechuic acid in rat plasma.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was developed for the quantitative determination of protocatechuic acid in rat plasma by high performance liquid chromatography (HPLC). With added p-hydroxybenzoic acid as internal standard, the plasma samples were extracted with a solvent mixture of methanol and acetonitrile ( 1: 5, v/v). The analyte was determined by HPLC with a Diamondsil C18 column and a mobile phase of acetonitrile-water (adjusted to pH 2.5 with H3PO4, 9: 91, v/v) at a flow rate of 1. 2 mL/min. The UV detection wavelength was 260 nm. The assay exhibited a good linearity in the concentration range from 0. 050 to 3. 20 mg/L with a correlation coefficient of 0. 997 8. The limit of quantification was 0. 050 mg/L. The relative standard deviations of intra-day and inter-day determination were both less than 7. 0% and the accuracy ranged from - 1. 4% to 2. 6%. The extraction recoveries of protocatechuic acid from rat plasma samples at three concentration levels were 83. 4%, 87. 3%, and 91. 1%, respectively. The developed method was applied to a pharmacokinetic study. The main pharmacokinetic parameters in rats after a single oral dose of 10 mL/kg body weight were as follows: Cmax of (3. 16 +0. 03) microg/mL, tmax of (0. 50 +/- 0. 00) h, AU0-->t of (39. 9 +/- 5. 9) microg x mL(-1) x h, AUC-->infinity of (54. 8 +/- 8. 1) microg x mL(-1) x h and t1/2 of (3. 87 +/- 0. 25) h. The method was proved to be simple, sensitive and accurate, thus suitable for the pharmacokinetic study of protocatechuic acid in rat plasma.

Key concepts: Chromatography, High-performance liquid chromatography, Chemistry, Protocatechuic acid, Detection limit, Acetonitrile, Extraction (chemistry), Cmax

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of protocatechuic acid in rat plasma by high performance liquid chromatography]. — Research Paper | ScholarLens