2015Journal of Hubei University of Chinese MedicineRequires access

Determintion of Isofraxidin in Gubisan by RP-HPLC

WU Yaohu

Open publisher page 0 citations

Abstract

Objective To analyze the content of Isofraxidin in Gubisan. Methods The DIONEX- C18column( 250 mm × 4. 6mm,5μm) was used. The mobile phase consisted of acetonitrile- 0. 1% phosphoric acid water( 25: 75). The flow rate was 1. 0m L / min. The column temperature was 30℃. The UV detector wavelength was 300 nm. Results The linear ranges of Isofraxidin was 10. 4208- 74. 1385μg( r= 0. 9997) with average recovery of 99. 1143%( RSD = 0. 6623%). Conclusions The method is stable,simple and simple,which could be used for the quality control and determination of content of Gubisan.

About this research paper

What this paper is about

Objective To analyze the content of Isofraxidin in Gubisan. Methods The DIONEX- C18column( 250 mm × 4. 6mm,5μm) was used. The mobile phase consisted of acetonitrile- 0. 1% phosphoric acid water( 25: 75). The flow rate was 1. 0m L / min. The column temperature was 30℃. The UV detector wavelength was 300 nm. Results The linear ranges of Isofraxidin was 10. 4208- 74. 1385μg( r= 0. 9997) with average recovery of 99. 1143%( RSD = 0. 6623%). Conclusions The method is stable,simple and simple,which could be used for the quality control and determination of content of Gubisan.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To analyze the content of Isofraxidin in Gubisan. Methods The DIONEX- C18column( 250 mm × 4. 6mm,5μm) was used. The mobile phase consisted of acetonitrile- 0. 1% phosphoric acid water( 25: 75). The flow rate was 1. 0m L / min. The column temperature was 30℃. The UV detector wavelength was 300 nm. Results The linear ranges of Isofraxidin was 10. 4208- 74. 1385μg( r= 0. 9997) with average recovery of 99. 1143%( RSD = 0. 6623%). Conclusions The method is stable,simple and simple,which could be used for the quality control and determination of content of Gubisan.

Key concepts: Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Acetonitrile, Content determination, Analytical Chemistry (journal), Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determintion of Isofraxidin in Gubisan by RP-HPLC — Research Paper | ScholarLens