Simplified method for determination of hexaflumuron residues in cotton and soil using QuEChERS and UPLC-MS/MS
Yongquan Zheng
Abstract
Yongquan Zheng
Abstract
A rapid method for the determination of hexaflumuron residues in cotton and soil was established based on matrix solid-phase dispersion(QuEChERS) and ultraperformance liquid chromatography-mass spectrometry(UPLC-MS/MS).The sample was extracted by acetonitrile and purified on primary secondary amine(PSA).The mass spectrometer was operated with electrospray in the opposite ion mode(ESI-).The target analytes were quantified by external standard method and matrix-matched standard solution used to compensate for matrix effect.Average recoveries of hexaflumuron in soil and corn samples were found in the range of 71.1%-110.0% at three spiking levels from 0.005 mg/kg to 0.5 mg/kg with relative standard deviations of 2.7%-8.4%.Limits of detections(LOD) of hexaflumuron on soil,cotton leaf and cotton seed were 0.04,0.12 and 0.22 μg/kg,while limits of quantifications(LOQ) were 0.14,0.41 and 0.74 μg/kg.The method is simple and suitable for the routine and confirmation analysis on cotton leaf,cotton seed and soil.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A rapid method for the determination of hexaflumuron residues in cotton and soil was established based on matrix solid-phase dispersion(QuEChERS) and ultraperformance liquid chromatography-mass spectrometry(UPLC-MS/MS).The sample was extracted by acetonitrile and purified on primary secondary amine(PSA).The mass spectrometer was operated with electrospray in the opposite ion mode(ESI-).The target analytes were quantified by external standard method and matrix-matched standard solution used to compensate for matrix effect.Average recoveries of hexaflumuron in soil and corn samples were found in the range of 71.1%-110.0% at three spiking levels from 0.005 mg/kg to 0.5 mg/kg with relative standard deviations of 2.7%-8.4%.Limits of detections(LOD) of hexaflumuron on soil,cotton leaf and cotton seed were 0.04,0.12 and 0.22 μg/kg,while limits of quantifications(LOQ) were 0.14,0.41 and 0.74 μg/kg.The method is simple and suitable for the routine and confirmation analysis on cotton leaf,cotton seed and soil.
Key concepts: Quechers, Chromatography, Chemistry, Matrix (chemical analysis), Mass spectrometry, Selected reaction monitoring, Residue (chemistry), Electrospray