2015•Zhongguo yaofangRequires access

Content Determination of Aprindine Hydrochloride Tablets and Its Related Substances by RP-HPLC

Xi Wang

Open publisher page 0 citations

Abstract

OBJECTIVE:To develop the method for the content determination of Aprindine hydrochloride tablets and its related substances. METHODS:RP-HPLC method was adopted. The determination was performed on Dikma Diamonsil C18 column with mobile phase consisted of methanol-water-10% tetrabutyl ammonium hydroxide(40∶60∶2.0,V/V/V,adjusted to 3.0 using phosphoric acid)at the flow rate of 1.0 ml/min. The detection wavelength was set at 258 nm,and column temperature was 30 ℃. Sample size was 10 μl. RESULTS:The linear range of aprindine hydrochloride were 25.55-204.40 μ g/ml(r=0.999 4);RSDs of precision,stability and reproducibility tests were lower than 0.6%;the average recovery was 100.1%(RSD=0.5%,n=9);the total amount of impurities was lower than 0.84%. CONCLUSIONS:The method is simple,accurate,specific and sensitive,and can be used for quality control of Aprindine hydrochloride tablets.

About this research paper

What this paper is about

OBJECTIVE:To develop the method for the content determination of Aprindine hydrochloride tablets and its related substances. METHODS:RP-HPLC method was adopted. The determination was performed on Dikma Diamonsil C18 column with mobile phase consisted of methanol-water-10% tetrabutyl ammonium hydroxide(40∶60∶2.0,V/V/V,adjusted to 3.0 using phosphoric acid)at the flow rate of 1.0 ml/min. The detection wavelength was set at 258 nm,and column temperature was 30 ℃. Sample size was 10 μl. RESULTS:The linear range of aprindine hydrochloride were 25.55-204.40 μ g/ml(r=0.999 4);RSDs of precision,stability and reproducibility tests were lower than 0.6%;the average recovery was 100.1%(RSD=0.5%,n=9);the total amount of impurities was lower than 0.84%. CONCLUSIONS:The method is simple,accurate,specific and sensitive,and can be used for quality control of Aprindine hydrochloride tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To develop the method for the content determination of Aprindine hydrochloride tablets and its related substances. METHODS:RP-HPLC method was adopted. The determination was performed on Dikma Diamonsil C18 column with mobile phase consisted of methanol-water-10% tetrabutyl ammonium hydroxide(40∶60∶2.0,V/V/V,adjusted to 3.0 using phosphoric acid)at the flow rate of 1.0 ml/min. The detection wavelength was set at 258 nm,and column temperature was 30 ℃. Sample size was 10 μl. RESULTS:The linear range of aprindine hydrochloride were 25.55-204.40 μ g/ml(r=0.999 4);RSDs of precision,stability and reproducibility tests were lower than 0.6%;the average recovery was 100.1%(RSD=0.5%,n=9);the total amount of impurities was lower than 0.84%. CONCLUSIONS:The method is simple,accurate,specific and sensitive,and can be used for quality control of Aprindine hydrochloride tablets.

Key concepts: Chemistry, Chromatography, Phosphoric acid, Content determination, High-performance liquid chromatography, Reproducibility, Ammonium hydroxide, Hydrochloride

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Aprindine Hydrochloride Tablets and Its Related Substances by RP-HPLC — Research Paper | ScholarLens