Application of dual source CT dual-energy angiography in cerebral blood vessels

Zhao Lin

Open publisher page 0 citations

Abstract

Objective:To explore the application of dual-energy CT in the examination of cerebral blood vessels. Methods:60 patients were divided into two groups randomly.Group A:30 patients,using the first generation dual source CT,140/80 kVp,55/243m As.Group B:30 patients,using the second generation dual source CT,80/Sn 140kVp,208/ 104 mAs.The average CT value of bilateral carotid artery,image noise,signal-to-noise ratio,contrast-to-noise ratio and subjective image quality score in the two groups were compared.At the same time,the CT volume dose index(CTDIvol),dose length product(DLP)and the effective dose(ED)were also compared.Statistics was made with group data of t test. Results:There was no significant difference of image quality between the two groups(P0.05)in the objective and subjective assessment.The differences of radiation dose between the two groups were significant statistically(P0.05),the effective dose in Group B[(0.27±0.01)mSv]was about 30% less than that in Group A[(0.37±0.02)mSv].Conclusion: Compared to the first generation dual-source CT,the radiation dose of cerebral vascular imaging can be reduced significantly by using the second generation dual-source CT,which won't lead to image quality reduction.

About this research paper

What this paper is about

Objective:To explore the application of dual-energy CT in the examination of cerebral blood vessels. Methods:60 patients were divided into two groups randomly.Group A:30 patients,using the first generation dual source CT,140/80 kVp,55/243m As.Group B:30 patients,using the second generation dual source CT,80/Sn 140kVp,208/ 104 mAs.The average CT value of bilateral carotid artery,image noise,signal-to-noise ratio,contrast-to-noise ratio and subjective image quality score in the two groups were compared.At the same time,the CT volume dose index(CTDIvol),dose length product(DLP)and the effective dose(ED)were also compared.Statistics was made with group data of t test. Results:There was no significant difference of image quality between the two groups(P0.05)in the objective and subjective assessment.The differences of radiation dose between the two groups were significant statistically(P0.05),the effective dose in Group B[(0.27±0.01)mSv]was about 30% less than that in Group A[(0.37±0.02)mSv].Conclusion: Compared to the first generation dual-source CT,the radiation dose of cerebral vascular imaging can be reduced significantly by using the second generation dual-source CT,which won't lead to image quality reduction.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To explore the application of dual-energy CT in the examination of cerebral blood vessels. Methods:60 patients were divided into two groups randomly.Group A:30 patients,using the first generation dual source CT,140/80 kVp,55/243m As.Group B:30 patients,using the second generation dual source CT,80/Sn 140kVp,208/ 104 mAs.The average CT value of bilateral carotid artery,image noise,signal-to-noise ratio,contrast-to-noise ratio and subjective image quality score in the two groups were compared.At the same time,the CT volume dose index(CTDIvol),dose length product(DLP)and the effective dose(ED)were also compared.Statistics was made with group data of t test. Results:There was no significant difference of image quality between the two groups(P0.05)in the objective and subjective assessment.The differences of radiation dose between the two groups were significant statistically(P0.05),the effective dose in Group B[(0.27±0.01)mSv]was about 30% less than that in Group A[(0.37±0.02)mSv].Conclusion: Compared to the first generation dual-source CT,the radiation dose of cerebral vascular imaging can be reduced significantly by using the second generation dual-source CT,which won't lead to image quality reduction.

Key concepts: Medicine, Image quality, Nuclear medicine, Radiation dose, Effective dose (radiation), Angiography, Radiology, Image noise

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of dual source CT dual-energy angiography in cerebral blood vessels — Research Paper | ScholarLens