Value of PET/CT in Diagnosis of the Recurrence and Metastasis of Head-and-neck Tumor after Treatment
Zhao Jin
Abstract
Zhao Jin
Abstract
Purpose:To assess the value of positron emission tomography/computed tomography (PET / CT) with ~(18)F-FDG in diagnosis of the recurrence and metastasis of head-and-neck tumor after treat- ment as compared with PET and CT alone.Materials and Methods:20 patients were retrospectively ana- lyzed.The performance of different imaging modalities was compared on a lesion-based analysis for sen- sitivity,specificity,and accuracy.Results:11 patients were detected with recurrence or metastasis. There were 105 malignant lesions detected in all and PET/CT detected 102,3 lesions were missed.The number of lesions detected by PET and CT was 77 and 68 respectively.The sensitivity,specificity,and accuracy of PET/CT,PET,CT is 97.1%,100%,97.6%;73.3%,60%,71.2%;64.8%,40%,60.8% respec- tively.Change of treatment according to PET/CT findings occurred in 4 patients (20%).Conclusion: PET/ CT has a high accuracy for diagnosis of the recurrence and metastasis of head-and-neck tumor, better than PET or CT alone,especially for patients with severe anatomic distortion after surgery or re- hictance to perform biopsy.PET/CT also had an important impact on clinical management of patients.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose:To assess the value of positron emission tomography/computed tomography (PET / CT) with ~(18)F-FDG in diagnosis of the recurrence and metastasis of head-and-neck tumor after treat- ment as compared with PET and CT alone.Materials and Methods:20 patients were retrospectively ana- lyzed.The performance of different imaging modalities was compared on a lesion-based analysis for sen- sitivity,specificity,and accuracy.Results:11 patients were detected with recurrence or metastasis. There were 105 malignant lesions detected in all and PET/CT detected 102,3 lesions were missed.The number of lesions detected by PET and CT was 77 and 68 respectively.The sensitivity,specificity,and accuracy of PET/CT,PET,CT is 97.1%,100%,97.6%;73.3%,60%,71.2%;64.8%,40%,60.8% respec- tively.Change of treatment according to PET/CT findings occurred in 4 patients (20%).Conclusion: PET/ CT has a high accuracy for diagnosis of the recurrence and metastasis of head-and-neck tumor, better than PET or CT alone,especially for patients with severe anatomic distortion after surgery or re- hictance to perform biopsy.PET/CT also had an important impact on clinical management of patients.
Key concepts: Medicine, Radiology, Positron emission tomography, Metastasis, Nuclear medicine, Biopsy, Head and neck, Lesion