The application of blood recovery and retrieval technology in emergency bleeding surgery
Lin Chen
Abstract
Lin Chen
Abstract
Objective To observe the effect of blood recovery and retrieval technology by using ZITI-3000 Autologous Blood Recovery System in emergency bleeding surgery.Methods Thirty patients undergoing emergency bleeding surgery was enrolled using ZITI-3000 Autologous Blood Recovery System from January 2011 to May 2012,the blood was cleaned for the recovery of blood more than 800 mL,the SBP,DBP,MBP,HR,SPO2,RBC,Hb and HCT was dectected during the patients enter the operation room,before blood transfusion,after blood transfusion and the patients leave the operation room.Results Blood recovery average of each patient was 1 910 mL,the average total return of the amount of blood transfusion was 678 mL,exception of one patient was died in hemorrhagic shock due to the inferior vena cava rupture but difficulties to suture in short time,the other patients' vital signs and hemoglobin were improved significantly.All patients with successful treatment did not occur with multiple organ dysfunction and transfusion-related complications.Conclusion ZITI-3000 Autologous Blood Recovery System is very useful and efficacious for decrease loss of blood during operation and complications of homologus blood trasfusion.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To observe the effect of blood recovery and retrieval technology by using ZITI-3000 Autologous Blood Recovery System in emergency bleeding surgery.Methods Thirty patients undergoing emergency bleeding surgery was enrolled using ZITI-3000 Autologous Blood Recovery System from January 2011 to May 2012,the blood was cleaned for the recovery of blood more than 800 mL,the SBP,DBP,MBP,HR,SPO2,RBC,Hb and HCT was dectected during the patients enter the operation room,before blood transfusion,after blood transfusion and the patients leave the operation room.Results Blood recovery average of each patient was 1 910 mL,the average total return of the amount of blood transfusion was 678 mL,exception of one patient was died in hemorrhagic shock due to the inferior vena cava rupture but difficulties to suture in short time,the other patients' vital signs and hemoglobin were improved significantly.All patients with successful treatment did not occur with multiple organ dysfunction and transfusion-related complications.Conclusion ZITI-3000 Autologous Blood Recovery System is very useful and efficacious for decrease loss of blood during operation and complications of homologus blood trasfusion.
Key concepts: Medicine, Blood transfusion, Surgery, Autologous blood, Anesthesia, Hemoglobin, Fibrous joint, Blood loss