2013Trace Elements ScienceRequires access

Determination of Arsenic and Cadmium in Water by Sequential Injection Hydride Generation Atom Fluorescence Spectrometry

Hui Zhao

Open publisher page 0 citations

Abstract

Objective To establish a method for simultaneous determination of arsenic and cadmium in water by sequential injection hydride generation-atomic fluorescence spectrometry.Method The influence of instrument parameters such as the negative high voltage on the photomultiplier,current of lamp,carrier gas rate,shield gas rate,sensitizer on the determination of arsenic and cadmium were studied.Result When the concentration of hydrochloric acid and potassium borohydride were 0.60 mol/L and 20 g/L respectively,the concentration of sensitizer sulfocarbamide and Co2+ were 80 g/L and 70 mg/L respectively,the effect of determination of arsenic and cadmium was perfect.Under the proposed conditions,the detection limits of arsenic and cadmium were 0.009 3 μg/L and 0.12 μg/L respectively.The standard addition recoveries for arsenic and cadmium were 92.3%~103.9%.The maximum RSD found was 3.5%.The coexistence ions in determined water samples did almost not interfere in the determination of arsenic and cadmium.Conclusion The operation of this method was easy and its sensitivity was higher.There are feasibility and practicability to determine arsenic and cadmium in water.

About this research paper

What this paper is about

Objective To establish a method for simultaneous determination of arsenic and cadmium in water by sequential injection hydride generation-atomic fluorescence spectrometry.Method The influence of instrument parameters such as the negative high voltage on the photomultiplier,current of lamp,carrier gas rate,shield gas rate,sensitizer on the determination of arsenic and cadmium were studied.Result When the concentration of hydrochloric acid and potassium borohydride were 0.60 mol/L and 20 g/L respectively,the concentration of sensitizer sulfocarbamide and Co2+ were 80 g/L and 70 mg/L respectively,the effect of determination of arsenic and cadmium was perfect.Under the proposed conditions,the detection limits of arsenic and cadmium were 0.009 3 μg/L and 0.12 μg/L respectively.The standard addition recoveries for arsenic and cadmium were 92.3%~103.9%.The maximum RSD found was 3.5%.The coexistence ions in determined water samples did almost not interfere in the determination of arsenic and cadmium.Conclusion The operation of this method was easy and its sensitivity was higher.There are feasibility and practicability to determine arsenic and cadmium in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for simultaneous determination of arsenic and cadmium in water by sequential injection hydride generation-atomic fluorescence spectrometry.Method The influence of instrument parameters such as the negative high voltage on the photomultiplier,current of lamp,carrier gas rate,shield gas rate,sensitizer on the determination of arsenic and cadmium were studied.Result When the concentration of hydrochloric acid and potassium borohydride were 0.60 mol/L and 20 g/L respectively,the concentration of sensitizer sulfocarbamide and Co2+ were 80 g/L and 70 mg/L respectively,the effect of determination of arsenic and cadmium was perfect.Under the proposed conditions,the detection limits of arsenic and cadmium were 0.009 3 μg/L and 0.12 μg/L respectively.The standard addition recoveries for arsenic and cadmium were 92.3%~103.9%.The maximum RSD found was 3.5%.The coexistence ions in determined water samples did almost not interfere in the determination of arsenic and cadmium.Conclusion The operation of this method was easy and its sensitivity was higher.There are feasibility and practicability to determine arsenic and cadmium in water.

Key concepts: Arsenic, Cadmium, Chemistry, Hydrochloric acid, Hydride, Detection limit, Fluorescence spectrometry, Fluorescence

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Arsenic and Cadmium in Water by Sequential Injection Hydride Generation Atom Fluorescence Spectrometry — Research Paper | ScholarLens