2008•Food ScienceRequires access

Study on Determination of Malachite Green in Aquatic Water by HPLC with Fluorescence Detector

Shi Hong

Open publisher page 0 citations

Abstract

HPLC with fluorescence detector method for the determination of malachite green(MG) and leucomalachite green in aquatic water was established. By orthogonal test the optimal extraction technology was establish. Reduction effect of KBH4 and limit of detection(LOD) of the method were studied. The optimal extraction conditions are extraction time 5 min,volume ratio of sample to dichloromethane 1:1 and extraction times two. MG can be completely reduced by 0.002 g KBH4. Good linear relationship ranges from 0.5 ng/ml to 800 ng/ml with correlation coefficient 0.99977. And the LOD is 0.2 μg/L. The recovery rates range from 86.8% to 93.3% with the relative standard deviations(RSD) of 3.15% to 8.12%. The method is suitable for the trace analysis of MG in aquatic water owing to its high efficiency and convenience.

About this research paper

What this paper is about

HPLC with fluorescence detector method for the determination of malachite green(MG) and leucomalachite green in aquatic water was established. By orthogonal test the optimal extraction technology was establish. Reduction effect of KBH4 and limit of detection(LOD) of the method were studied. The optimal extraction conditions are extraction time 5 min,volume ratio of sample to dichloromethane 1:1 and extraction times two. MG can be completely reduced by 0.002 g KBH4. Good linear relationship ranges from 0.5 ng/ml to 800 ng/ml with correlation coefficient 0.99977. And the LOD is 0.2 μg/L. The recovery rates range from 86.8% to 93.3% with the relative standard deviations(RSD) of 3.15% to 8.12%. The method is suitable for the trace analysis of MG in aquatic water owing to its high efficiency and convenience.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

HPLC with fluorescence detector method for the determination of malachite green(MG) and leucomalachite green in aquatic water was established. By orthogonal test the optimal extraction technology was establish. Reduction effect of KBH4 and limit of detection(LOD) of the method were studied. The optimal extraction conditions are extraction time 5 min,volume ratio of sample to dichloromethane 1:1 and extraction times two. MG can be completely reduced by 0.002 g KBH4. Good linear relationship ranges from 0.5 ng/ml to 800 ng/ml with correlation coefficient 0.99977. And the LOD is 0.2 μg/L. The recovery rates range from 86.8% to 93.3% with the relative standard deviations(RSD) of 3.15% to 8.12%. The method is suitable for the trace analysis of MG in aquatic water owing to its high efficiency and convenience.

Key concepts: Malachite green, Detection limit, Chromatography, Extraction (chemistry), High-performance liquid chromatography, Chemistry, Correlation coefficient, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Determination of Malachite Green in Aquatic Water by HPLC with Fluorescence Detector — Research Paper | ScholarLens