2007•Chinese Remedies & ClinicsRequires access

The stability measurement of chlorine dioxide solution

Xi Li

Open publisher page 1 citations

Abstract

Objective To determine the stability of chlorine dioxide solution and provide a technical basis to disinfection procedures for mouth impression. Methods Five-step iodometry was used to determine the concentration of chlorine dioxide, and UV-spectrophotometry was applied to detect the stability of chlorine dioxide solution. Results Over a half-year period, non-activated raw solution of chlorine dioxide degraded by 2.01% at 4℃ and by 2.65% at 25℃, as shown by comparative measurements. At room temperature, 0.05% activated chlorine dioxide solution degraded by 8.56% at 12 hours after preparation. Conclusion Non-activated chlorine dioxide solution appeared to be more stable at low temperature than at room temperature. Activated chlorine dioxide solution for disinfection of mouth impression should be prepared at service time.

About this research paper

What this paper is about

Objective To determine the stability of chlorine dioxide solution and provide a technical basis to disinfection procedures for mouth impression. Methods Five-step iodometry was used to determine the concentration of chlorine dioxide, and UV-spectrophotometry was applied to detect the stability of chlorine dioxide solution. Results Over a half-year period, non-activated raw solution of chlorine dioxide degraded by 2.01% at 4℃ and by 2.65% at 25℃, as shown by comparative measurements. At room temperature, 0.05% activated chlorine dioxide solution degraded by 8.56% at 12 hours after preparation. Conclusion Non-activated chlorine dioxide solution appeared to be more stable at low temperature than at room temperature. Activated chlorine dioxide solution for disinfection of mouth impression should be prepared at service time.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To determine the stability of chlorine dioxide solution and provide a technical basis to disinfection procedures for mouth impression. Methods Five-step iodometry was used to determine the concentration of chlorine dioxide, and UV-spectrophotometry was applied to detect the stability of chlorine dioxide solution. Results Over a half-year period, non-activated raw solution of chlorine dioxide degraded by 2.01% at 4℃ and by 2.65% at 25℃, as shown by comparative measurements. At room temperature, 0.05% activated chlorine dioxide solution degraded by 8.56% at 12 hours after preparation. Conclusion Non-activated chlorine dioxide solution appeared to be more stable at low temperature than at room temperature. Activated chlorine dioxide solution for disinfection of mouth impression should be prepared at service time.

Key concepts: Chlorine dioxide, Iodometry, Chlorine, Chemistry, Inorganic chemistry, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
The stability measurement of chlorine dioxide solution — Research Paper | ScholarLens