2002•Advanced Technology of Electrical Engineering and EnergyRequires access

A balance control method and signal detection needed for SVC control

Xiu Liu

Open publisher page 0 citations

Abstract

A balance control method and signal detection needed for static var compensator (SVC) control under the conditions of symmetrical and unsymmetrical voltages or currents with or without distortions are described in this paper. Based on the instantaneous power concept the detection method for the required signals such as the root\|mean\|square value of the voltage and the reactive current, the reactive power and the power factor is developed in detail. The simulations and the practical application in the design of a SVC model have shown that the proposed method is very effective, accurate, and with fast response performance.

About this research paper

What this paper is about

A balance control method and signal detection needed for static var compensator (SVC) control under the conditions of symmetrical and unsymmetrical voltages or currents with or without distortions are described in this paper. Based on the instantaneous power concept the detection method for the required signals such as the root\|mean\|square value of the voltage and the reactive current, the reactive power and the power factor is developed in detail. The simulations and the practical application in the design of a SVC model have shown that the proposed method is very effective, accurate, and with fast response performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A balance control method and signal detection needed for static var compensator (SVC) control under the conditions of symmetrical and unsymmetrical voltages or currents with or without distortions are described in this paper. Based on the instantaneous power concept the detection method for the required signals such as the root\|mean\|square value of the voltage and the reactive current, the reactive power and the power factor is developed in detail. The simulations and the practical application in the design of a SVC model have shown that the proposed method is very effective, accurate, and with fast response performance.

Key concepts: Control theory (sociology), Static VAR compensator, AC power, Root mean square, SIGNAL (programming language), Voltage, Power (physics), Power factor

Related papers

Back to paper searchBrowse research topicsOriginal source
A balance control method and signal detection needed for SVC control — Research Paper | ScholarLens