2008Tianranqi gongyeRequires access

ANALYSIS ON THE REASONS FOR THE GAS WELL TUBING BLOCKING CAUSED BY CORROSION INHIBITOR AND ITS COUNTERMEASURES

HU De-fen

Open publisher page 0 citations

Abstract

Under current technical conditions, to add proper corrosion inhibitor is the most economical and effective protective measures to protect the down-hole oil and casing in sour gas wells. The selection of corrosion inhibitor should have its pertinence, which means different corrosion inhibitors would be chosen according to different corrosion factors to gas wells. In view of the tubing blocking caused by corrosion inhibitor appeared in the eastern Sichuan basin in recent years and its practical field solutions,combined with the analysis on the underground scale and inference to the stemming in the process of removing plugging, the paper summarized the main reasons that the corrosion inhibitor causes tubing blocking, which include the poor adaptability of corrosion inhibitor, the unreasonable adding system, the defect of corrosion inhibitor quality, as well as the wrapping and clip of corrosion product. It is proposed that a compatibility type experiment should be taken before putting corrosion inhibitor into wells and regular well cleanout should be implemented to the gas wells adding corrosion inhibitor. Meanwhile, strengthening the control of corrosion inhibitor quality, field and production management, are put forward to ensure that the corrosion can be delayed in the gas wells where suitable corrosion inhibitor is added and shaft blocking caused by corrosion inhibitor can be reduced as much as possible, which provide basis for production decisions.

About this research paper

What this paper is about

Under current technical conditions, to add proper corrosion inhibitor is the most economical and effective protective measures to protect the down-hole oil and casing in sour gas wells. The selection of corrosion inhibitor should have its pertinence, which means different corrosion inhibitors would be chosen according to different corrosion factors to gas wells. In view of the tubing blocking caused by corrosion inhibitor appeared in the eastern Sichuan basin in recent years and its practical field solutions,combined with the analysis on the underground scale and inference to the stemming in the process of removing plugging, the paper summarized the main reasons that the corrosion inhibitor causes tubing blocking, which include the poor adaptability of corrosion inhibitor, the unreasonable adding system, the defect of corrosion inhibitor quality, as well as the wrapping and clip of corrosion product. It is proposed that a compatibility type experiment should be taken before putting corrosion inhibitor into wells and regular well cleanout should be implemented to the gas wells adding corrosion inhibitor. Meanwhile, strengthening the control of corrosion inhibitor quality, field and production management, are put forward to ensure that the corrosion can be delayed in the gas wells where suitable corrosion inhibitor is added and shaft blocking caused by corrosion inhibitor can be reduced as much as possible, which provide basis for production decisions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Under current technical conditions, to add proper corrosion inhibitor is the most economical and effective protective measures to protect the down-hole oil and casing in sour gas wells. The selection of corrosion inhibitor should have its pertinence, which means different corrosion inhibitors would be chosen according to different corrosion factors to gas wells. In view of the tubing blocking caused by corrosion inhibitor appeared in the eastern Sichuan basin in recent years and its practical field solutions,combined with the analysis on the underground scale and inference to the stemming in the process of removing plugging, the paper summarized the main reasons that the corrosion inhibitor causes tubing blocking, which include the poor adaptability of corrosion inhibitor, the unreasonable adding system, the defect of corrosion inhibitor quality, as well as the wrapping and clip of corrosion product. It is proposed that a compatibility type experiment should be taken before putting corrosion inhibitor into wells and regular well cleanout should be implemented to the gas wells adding corrosion inhibitor. Meanwhile, strengthening the control of corrosion inhibitor quality, field and production management, are put forward to ensure that the corrosion can be delayed in the gas wells where suitable corrosion inhibitor is added and shaft blocking caused by corrosion inhibitor can be reduced as much as possible, which provide basis for production decisions.

Key concepts: Corrosion, Corrosion inhibitor, Casing, Metallurgy, Petroleum engineering, Materials science, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
ANALYSIS ON THE REASONS FOR THE GAS WELL TUBING BLOCKING CAUSED BY CORROSION INHIBITOR AND ITS COUNTERMEASURES — Research Paper | ScholarLens