2009•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Fluorene Derivatives 2-Bromofluorenone by High Performance Liquid Chromatography

Rui Zhao

Open publisher page 1 citations

Abstract

2-Bromofluorenone was determined by high performance liquid chromatography with the chromatographic conditions of dalian Elite Hypersil ODS2 C18 column(4.6×250mm);the mobile phase of methanol-water(85∶15 V/V);the flow rate was 1.0mL/min;the detection wavelength was 254nm and column at 40℃.A good liner relationship was obtained within the range of 1.0—10.0mg/L of 2-bromofluorenone(r=0.9992);the average recovery rate was 99.22% and the RSD was lower than 1%.It was shown that the established method was rapid and reliable,providing an analysis method for the industrial preparation of 2-bromofluorenone.

About this research paper

What this paper is about

2-Bromofluorenone was determined by high performance liquid chromatography with the chromatographic conditions of dalian Elite Hypersil ODS2 C18 column(4.6×250mm);the mobile phase of methanol-water(85∶15 V/V);the flow rate was 1.0mL/min;the detection wavelength was 254nm and column at 40℃.A good liner relationship was obtained within the range of 1.0—10.0mg/L of 2-bromofluorenone(r=0.9992);the average recovery rate was 99.22% and the RSD was lower than 1%.It was shown that the established method was rapid and reliable,providing an analysis method for the industrial preparation of 2-bromofluorenone.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

2-Bromofluorenone was determined by high performance liquid chromatography with the chromatographic conditions of dalian Elite Hypersil ODS2 C18 column(4.6×250mm);the mobile phase of methanol-water(85∶15 V/V);the flow rate was 1.0mL/min;the detection wavelength was 254nm and column at 40℃.A good liner relationship was obtained within the range of 1.0—10.0mg/L of 2-bromofluorenone(r=0.9992);the average recovery rate was 99.22% and the RSD was lower than 1%.It was shown that the established method was rapid and reliable,providing an analysis method for the industrial preparation of 2-bromofluorenone.

Key concepts: Chromatography, Fluorene, High-performance liquid chromatography, Chemistry, Methanol, Volumetric flow rate, Phase (matter), Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Fluorene Derivatives 2-Bromofluorenone by High Performance Liquid Chromatography — Research Paper | ScholarLens