Evaluation on the performance of the Olympus AU5400 automatic biochemistry analyzer

Lin Son

Open publisher page 0 citations

Abstract

Objective To analyze the performance characteristics of Olympus AU5400 biochemistry analyzer,and to identify whether the performance is acceptable for the goals of laboratory performance.Methods In accordance with the clinical laboratory principle and the requirement of accreditation of national laboratory,the precision and accuracy of the 6 test methods(ALT,AST,TP,Glu,K+,Na+)were identified by the CLSI EP5-A2 document and CLSI EP9-A2 document;According to CLSI EP6-P document,the linear range of ALT,AST,TP and Glu in the two unites were analyzed,validating the reference range of the 6 test methods.Results The within-batch precision of ALT,AST,TP,Glu,K+,Na+ are lower than that of the quarter of CLIA'88 and the total precision are lower than one-third of CLIA'88;the correlation of the 6 test methods between the two unites of the Olympus AU5400 systems and the Olympus AU640 systems was fairly good(r20.95)in the method comparison test,and the relative biases of all items could be accepted at different medical determinate level according to the half of CLIA'88 standard;The linearity of ALT,AST,TP,Glu in two unites of the Olympus AU5400 systems was also good in the linear range(r20.95);The reference range of the 6 test methods cited in our laboratory were satisfied.Conclusion The Olympus AU5400 automatic biochemistry analyzer satisfy the needs of the laboratory performance.

About this research paper

What this paper is about

Objective To analyze the performance characteristics of Olympus AU5400 biochemistry analyzer,and to identify whether the performance is acceptable for the goals of laboratory performance.Methods In accordance with the clinical laboratory principle and the requirement of accreditation of national laboratory,the precision and accuracy of the 6 test methods(ALT,AST,TP,Glu,K+,Na+)were identified by the CLSI EP5-A2 document and CLSI EP9-A2 document;According to CLSI EP6-P document,the linear range of ALT,AST,TP and Glu in the two unites were analyzed,validating the reference range of the 6 test methods.Results The within-batch precision of ALT,AST,TP,Glu,K+,Na+ are lower than that of the quarter of CLIA'88 and the total precision are lower than one-third of CLIA'88;the correlation of the 6 test methods between the two unites of the Olympus AU5400 systems and the Olympus AU640 systems was fairly good(r20.95)in the method comparison test,and the relative biases of all items could be accepted at different medical determinate level according to the half of CLIA'88 standard;The linearity of ALT,AST,TP,Glu in two unites of the Olympus AU5400 systems was also good in the linear range(r20.95);The reference range of the 6 test methods cited in our laboratory were satisfied.Conclusion The Olympus AU5400 automatic biochemistry analyzer satisfy the needs of the laboratory performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To analyze the performance characteristics of Olympus AU5400 biochemistry analyzer,and to identify whether the performance is acceptable for the goals of laboratory performance.Methods In accordance with the clinical laboratory principle and the requirement of accreditation of national laboratory,the precision and accuracy of the 6 test methods(ALT,AST,TP,Glu,K+,Na+)were identified by the CLSI EP5-A2 document and CLSI EP9-A2 document;According to CLSI EP6-P document,the linear range of ALT,AST,TP and Glu in the two unites were analyzed,validating the reference range of the 6 test methods.Results The within-batch precision of ALT,AST,TP,Glu,K+,Na+ are lower than that of the quarter of CLIA'88 and the total precision are lower than one-third of CLIA'88;the correlation of the 6 test methods between the two unites of the Olympus AU5400 systems and the Olympus AU640 systems was fairly good(r20.95)in the method comparison test,and the relative biases of all items could be accepted at different medical determinate level according to the half of CLIA'88 standard;The linearity of ALT,AST,TP,Glu in two unites of the Olympus AU5400 systems was also good in the linear range(r20.95);The reference range of the 6 test methods cited in our laboratory were satisfied.Conclusion The Olympus AU5400 automatic biochemistry analyzer satisfy the needs of the laboratory performance.

Key concepts: Spectrum analyzer, Computer science, Mathematics, Telecommunications

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation on the performance of the Olympus AU5400 automatic biochemistry analyzer — Research Paper | ScholarLens