2011•Chinese Journal of Health Laboratory TechnologyRequires access

Determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection

Lijing Liu

Open publisher page 0 citations

Abstract

Objective:To develop a method for determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection.Methods: The method was based on large volume injection and IC separation under the condition of gradient eluent with 10 mmol/L~35 mmol/L KOH generation on line and flow rate of 1.0 ml/min by using the IonPac AS19 analytical column and suppressed condutivity detector.Results:This method had good linear relatity in the range of 0 mg/L~0.10 mg/L and good analytic precision(RSD%3.0).The correlation coefficient was 0.9996 for bromate and 0.9992 for bromide.The recovery rate was 97.0%~104.5% for bromate and 92.0%~105.5% for bromide.The detection limit was 0.78 μg/L for bromate and 0.25 μg/L for bromide.Conclusion: This method is sensitive,rapid and simple.It is available to determine the bromate and bromide in bottled drinking water by free reagent ion chromatography.

About this research paper

What this paper is about

Objective:To develop a method for determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection.Methods: The method was based on large volume injection and IC separation under the condition of gradient eluent with 10 mmol/L~35 mmol/L KOH generation on line and flow rate of 1.0 ml/min by using the IonPac AS19 analytical column and suppressed condutivity detector.Results:This method had good linear relatity in the range of 0 mg/L~0.10 mg/L and good analytic precision(RSD%3.0).The correlation coefficient was 0.9996 for bromate and 0.9992 for bromide.The recovery rate was 97.0%~104.5% for bromate and 92.0%~105.5% for bromide.The detection limit was 0.78 μg/L for bromate and 0.25 μg/L for bromide.Conclusion: This method is sensitive,rapid and simple.It is available to determine the bromate and bromide in bottled drinking water by free reagent ion chromatography.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To develop a method for determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection.Methods: The method was based on large volume injection and IC separation under the condition of gradient eluent with 10 mmol/L~35 mmol/L KOH generation on line and flow rate of 1.0 ml/min by using the IonPac AS19 analytical column and suppressed condutivity detector.Results:This method had good linear relatity in the range of 0 mg/L~0.10 mg/L and good analytic precision(RSD%3.0).The correlation coefficient was 0.9996 for bromate and 0.9992 for bromide.The recovery rate was 97.0%~104.5% for bromate and 92.0%~105.5% for bromide.The detection limit was 0.78 μg/L for bromate and 0.25 μg/L for bromide.Conclusion: This method is sensitive,rapid and simple.It is available to determine the bromate and bromide in bottled drinking water by free reagent ion chromatography.

Key concepts: Bromate, Reagent, Bromide, Chemistry, Chromatography, Detection limit, Bottled water, Ion chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection — Research Paper | ScholarLens