Evaluation of reclaiming technology for gas-fired boiler flue gas residual heat

Xiaohui Zhang

Open publisher page 2 citations

Abstract

A series of calculations were carried out to explore the thermal efficiency performance during flue gas condensation based on the natural gas boiler model,the relationships of gas thermal efficiency with flue gas-temperature,air factor were discussed.It was meaningfully to recover the flue gas thermal energy when the flue gas temperature reached the dew point of flue gas,which could be implemented by adding a condensation energy heat-exchanger,the structures of condensing heat transfer equipment were discussed on heat transfer,flow resistance and Iow temperature corrosion.

About this research paper

What this paper is about

A series of calculations were carried out to explore the thermal efficiency performance during flue gas condensation based on the natural gas boiler model,the relationships of gas thermal efficiency with flue gas-temperature,air factor were discussed.It was meaningfully to recover the flue gas thermal energy when the flue gas temperature reached the dew point of flue gas,which could be implemented by adding a condensation energy heat-exchanger,the structures of condensing heat transfer equipment were discussed on heat transfer,flow resistance and Iow temperature corrosion.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A series of calculations were carried out to explore the thermal efficiency performance during flue gas condensation based on the natural gas boiler model,the relationships of gas thermal efficiency with flue gas-temperature,air factor were discussed.It was meaningfully to recover the flue gas thermal energy when the flue gas temperature reached the dew point of flue gas,which could be implemented by adding a condensation energy heat-exchanger,the structures of condensing heat transfer equipment were discussed on heat transfer,flow resistance and Iow temperature corrosion.

Key concepts: Flue gas, Dew point, Boiler (water heating), Heat exchanger, Natural gas, Flue-gas emissions from fossil-fuel combustion, Air preheater, Heat transfer

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of reclaiming technology for gas-fired boiler flue gas residual heat — Research Paper | ScholarLens