Analysis on comparability of part of the detecting results of serum enzyme by different detection systems in two hospitals
Xie Su-yu
Abstract
Xie Su-yu
Abstract
Objective To analyze the comparability of detecting results of serum enzyme by different detection systems in different hospitals.Methods According the reference standard in NCCLS EP9-A2,the system consisted Hitachi 7080 biochemical analyzer,Roche reagents,Cfas calibrator and quality control materials was the target detection system.The other one to three detection systems in the two hospitals were the experimental system.The levels of alanine aminotransferase(ALT),alkaline phosphatase(ALP),aspartate aminotransferase(AST),and gamma-glutamyl transferase(GGT) were detected.The relative deviation(SE %) between laboratory method(Y) and comparison method(X) was used to judge the comparability of different detection systems.When the bias was not acceptable,a fresh mixed serum was assayed,and the result was adopted as temporary calibrator of the detection system.Results In addition to the bias of GGT result of detection system 2 was too great,and the result was unacceptable.The results of the other detection system were acceptable.After the temporary calibrator using,the bias was significantly decreased and acceptable in system 2.Conclusion The same samples detected by different detection systems in different hospitals should be performed in method comparison and bias evaluation to conduct clinical acceptability.The deassign using fresh mixed serum can ensure the comparability of different systems.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To analyze the comparability of detecting results of serum enzyme by different detection systems in different hospitals.Methods According the reference standard in NCCLS EP9-A2,the system consisted Hitachi 7080 biochemical analyzer,Roche reagents,Cfas calibrator and quality control materials was the target detection system.The other one to three detection systems in the two hospitals were the experimental system.The levels of alanine aminotransferase(ALT),alkaline phosphatase(ALP),aspartate aminotransferase(AST),and gamma-glutamyl transferase(GGT) were detected.The relative deviation(SE %) between laboratory method(Y) and comparison method(X) was used to judge the comparability of different detection systems.When the bias was not acceptable,a fresh mixed serum was assayed,and the result was adopted as temporary calibrator of the detection system.Results In addition to the bias of GGT result of detection system 2 was too great,and the result was unacceptable.The results of the other detection system were acceptable.After the temporary calibrator using,the bias was significantly decreased and acceptable in system 2.Conclusion The same samples detected by different detection systems in different hospitals should be performed in method comparison and bias evaluation to conduct clinical acceptability.The deassign using fresh mixed serum can ensure the comparability of different systems.
Key concepts: Comparability, Alanine aminotransferase, Spectrum analyzer, Detection limit, Alkaline phosphatase, Chromatography, Mathematics, Computer science