Determination of the Blood Concentration of Mycophenolate Mofetil in Lupus Nephritis Patients by HPLC
Xu Yi
Abstract
Xu Yi
Abstract
OBJECTIVE:To determine the blood concentration of mycophenolate mofetil(MMF)in the lupus nephritis(LN)patients. METHODS:HPLC was used for determining MMF metabolite mycophenolic acid(MPA)after blood sample of LN patients trated. SGE Protecol C18 column was used with mobile phase consisted of methanol-acetonitrile0.01% phosphoric acid(23 ∶ 37 ∶ 40,V/V/V)at the flow rate of 1.0 ml/min. The detection wavelength was set at 216 nm,and injection volume was 20 μl. The column temperature was 30 ℃. RESULTS:The linear range of MPA was 0.125-10 mg/L(r=0.999 9)with method recovery of 98.67%-104.31% and extraction recovery of 83.43% -97.54% . The extraction recovery of internal standard(nimesulide)was 79.35% . RSDs of inter-day and intra-day were 2.6%-7.7% and 2.3%-8.5%,respectively. CONCLUSIONS:The method is simple and accurate,and can be used for blood concentrations monitoring of MPA in LN patients after taking MMF.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE:To determine the blood concentration of mycophenolate mofetil(MMF)in the lupus nephritis(LN)patients. METHODS:HPLC was used for determining MMF metabolite mycophenolic acid(MPA)after blood sample of LN patients trated. SGE Protecol C18 column was used with mobile phase consisted of methanol-acetonitrile0.01% phosphoric acid(23 ∶ 37 ∶ 40,V/V/V)at the flow rate of 1.0 ml/min. The detection wavelength was set at 216 nm,and injection volume was 20 μl. The column temperature was 30 ℃. RESULTS:The linear range of MPA was 0.125-10 mg/L(r=0.999 9)with method recovery of 98.67%-104.31% and extraction recovery of 83.43% -97.54% . The extraction recovery of internal standard(nimesulide)was 79.35% . RSDs of inter-day and intra-day were 2.6%-7.7% and 2.3%-8.5%,respectively. CONCLUSIONS:The method is simple and accurate,and can be used for blood concentrations monitoring of MPA in LN patients after taking MMF.
Key concepts: Mycophenolate, Mycophenolic acid, Chromatography, Phosphoric acid, Lupus nephritis, Chemistry, High-performance liquid chromatography, Nimesulide