2012PubMedRequires access

[Determination of impurity elements in edible phosphate by ICP-MS].

Tan-ping Li, Xie Hua-lin

Open publisher page 0 citations

Abstract

An octopole reaction system (ORS) inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of Mg, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in edible phosphate. The sample was digested by HNO3 followed by dilution with ultrapure water, then the above 12 impurity elements in the solution were analyzed directly by ICP-MS The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Y, In and Bi were used to correct the matrix interference and drift. The detection limits of the 12 elements are in the range of 0.004-0.362 microg x L(-1). This method is rapid, simple and applicable for the analysis of trace elements in edible phosphate.

About this research paper

What this paper is about

An octopole reaction system (ORS) inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of Mg, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in edible phosphate. The sample was digested by HNO3 followed by dilution with ultrapure water, then the above 12 impurity elements in the solution were analyzed directly by ICP-MS The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Y, In and Bi were used to correct the matrix interference and drift. The detection limits of the 12 elements are in the range of 0.004-0.362 microg x L(-1). This method is rapid, simple and applicable for the analysis of trace elements in edible phosphate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An octopole reaction system (ORS) inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of Mg, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in edible phosphate. The sample was digested by HNO3 followed by dilution with ultrapure water, then the above 12 impurity elements in the solution were analyzed directly by ICP-MS The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Y, In and Bi were used to correct the matrix interference and drift. The detection limits of the 12 elements are in the range of 0.004-0.362 microg x L(-1). This method is rapid, simple and applicable for the analysis of trace elements in edible phosphate.

Key concepts: Ultrapure water, Inductively coupled plasma mass spectrometry, Polyatomic ion, Chemistry, Impurity, Dilution, Analytical Chemistry (journal), Phosphate

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of impurity elements in edible phosphate by ICP-MS]. — Research Paper | ScholarLens