2009Research and Practice on Chinese MedicinesRequires access

Determination of Trans-ferulic Acid and Cis-ferulic Acid in 7 Medicinal Materials by RP-HPLC

Tong Yong-bin

Open publisher page 0 citations

Abstract

Objective To develop HPLC method for determination of trans-ferulic acid and cis-ferulic acid in 7 medicinal materials .Methods Analysis was carried out on a C18 (4.6mm×250mm,5μm)column eluled with acetonitrile-0.3 % acetic acid (20:80) as the mobile phase , the detection wavelength was set at 320 nm. Results The linear relationship of ferulic acid was in the range of 0.028 5~0.513 μg ( r = 0.999 9) ,the recovery was 98.17% ,RSD was 0.73%( n = 6). Conclusion The method is simple ,accurate and reproducible, and can be used for the analysis of ferulic acid in medicinal materials

About this research paper

What this paper is about

Objective To develop HPLC method for determination of trans-ferulic acid and cis-ferulic acid in 7 medicinal materials .Methods Analysis was carried out on a C18 (4.6mm×250mm,5μm)column eluled with acetonitrile-0.3 % acetic acid (20:80) as the mobile phase , the detection wavelength was set at 320 nm. Results The linear relationship of ferulic acid was in the range of 0.028 5~0.513 μg ( r = 0.999 9) ,the recovery was 98.17% ,RSD was 0.73%( n = 6). Conclusion The method is simple ,accurate and reproducible, and can be used for the analysis of ferulic acid in medicinal materials

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop HPLC method for determination of trans-ferulic acid and cis-ferulic acid in 7 medicinal materials .Methods Analysis was carried out on a C18 (4.6mm×250mm,5μm)column eluled with acetonitrile-0.3 % acetic acid (20:80) as the mobile phase , the detection wavelength was set at 320 nm. Results The linear relationship of ferulic acid was in the range of 0.028 5~0.513 μg ( r = 0.999 9) ,the recovery was 98.17% ,RSD was 0.73%( n = 6). Conclusion The method is simple ,accurate and reproducible, and can be used for the analysis of ferulic acid in medicinal materials

Key concepts: Ferulic acid, Chromatography, High-performance liquid chromatography, Acetic acid, Acetonitrile, Chemistry, Linear range, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trans-ferulic Acid and Cis-ferulic Acid in 7 Medicinal Materials by RP-HPLC — Research Paper | ScholarLens