2010Metallurgical AnalysisRequires access

Determination of impurity elements in silicon carbide by inductively coupled plasma atomic emission spectrometry

Yao Yong-sheng

Open publisher page 0 citations

Abstract

A method was proposed for the simultaneous determination of micro Fe,Al,Ti,Ca,Mg,P and Mn in silicon carbide by inductively coupled plasma atomic emission spectrometry.The sample was fused with the mixed fluxing agent of anhydrous sodium carbonate-boric acid,and extracted by nitric acid.The boron was removed by methanol,and silicon was removed by volatilization with hydrofluoric acid.The sample solution was determined under the selected instrumental conditions.The interference of matrix was corrected by matrix matching method.The detection limits of testing elements were 0.001-0.054 μg/mL,and the relative standard deviation(RSD,n=9) was 0.5 %-3.7 %.By the comparison,it was found that the results of this method were consistent with those obtained by other methods.

About this research paper

What this paper is about

A method was proposed for the simultaneous determination of micro Fe,Al,Ti,Ca,Mg,P and Mn in silicon carbide by inductively coupled plasma atomic emission spectrometry.The sample was fused with the mixed fluxing agent of anhydrous sodium carbonate-boric acid,and extracted by nitric acid.The boron was removed by methanol,and silicon was removed by volatilization with hydrofluoric acid.The sample solution was determined under the selected instrumental conditions.The interference of matrix was corrected by matrix matching method.The detection limits of testing elements were 0.001-0.054 μg/mL,and the relative standard deviation(RSD,n=9) was 0.5 %-3.7 %.By the comparison,it was found that the results of this method were consistent with those obtained by other methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was proposed for the simultaneous determination of micro Fe,Al,Ti,Ca,Mg,P and Mn in silicon carbide by inductively coupled plasma atomic emission spectrometry.The sample was fused with the mixed fluxing agent of anhydrous sodium carbonate-boric acid,and extracted by nitric acid.The boron was removed by methanol,and silicon was removed by volatilization with hydrofluoric acid.The sample solution was determined under the selected instrumental conditions.The interference of matrix was corrected by matrix matching method.The detection limits of testing elements were 0.001-0.054 μg/mL,and the relative standard deviation(RSD,n=9) was 0.5 %-3.7 %.By the comparison,it was found that the results of this method were consistent with those obtained by other methods.

Key concepts: Inductively coupled plasma, Analytical Chemistry (journal), Hydrofluoric acid, Nitric acid, Chemistry, Boric acid, Matrix (chemical analysis), Inductively coupled plasma atomic emission spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of impurity elements in silicon carbide by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens