Determination of trace boron in industrial silicon by inductively coupled plasma atomic emission spectrometry
Lin Wei-tao
Abstract
Lin Wei-tao
Abstract
Trace boron in industrial silicon was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after the sample was decomposed with HNO3-HF mixed acid. The results showed that the volatilization of boron could be effectively inhibited by controlling the heating temperature at 140-180 ℃. The analytical spectral lines were investigated, and B 208.9 nm{161}was selected. Moreover, by properly deducting the background under the experimental conditions, the matrix and other coexiting elements had no interference with the spectra of B 208.9 nm{161}. Under the optimal working conditions of instrument, the detection limit of method was 0.03 μg/mL and the recovery was 90 %-105 % with the relative standard deviation (RSD) of no more than 7.0 % (n=11). The proposed method has been applied to the determination of boron in industrial silicon certified reference materials, and the results were consistent with the certified values.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Trace boron in industrial silicon was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after the sample was decomposed with HNO3-HF mixed acid. The results showed that the volatilization of boron could be effectively inhibited by controlling the heating temperature at 140-180 ℃. The analytical spectral lines were investigated, and B 208.9 nm{161}was selected. Moreover, by properly deducting the background under the experimental conditions, the matrix and other coexiting elements had no interference with the spectra of B 208.9 nm{161}. Under the optimal working conditions of instrument, the detection limit of method was 0.03 μg/mL and the recovery was 90 %-105 % with the relative standard deviation (RSD) of no more than 7.0 % (n=11). The proposed method has been applied to the determination of boron in industrial silicon certified reference materials, and the results were consistent with the certified values.
Key concepts: Boron, Analytical Chemistry (journal), Inductively coupled plasma, Detection limit, Silicon, Volatilisation, Inductively coupled plasma atomic emission spectroscopy, Chemistry