2010Metallurgical AnalysisRequires access

Determination of trace boron in industrial silicon by inductively coupled plasma atomic emission spectrometry

Lin Wei-tao

Open publisher page 0 citations

Abstract

Trace boron in industrial silicon was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after the sample was decomposed with HNO3-HF mixed acid. The results showed that the volatilization of boron could be effectively inhibited by controlling the heating temperature at 140-180 ℃. The analytical spectral lines were investigated, and B 208.9 nm{161}was selected. Moreover, by properly deducting the background under the experimental conditions, the matrix and other coexiting elements had no interference with the spectra of B 208.9 nm{161}. Under the optimal working conditions of instrument, the detection limit of method was 0.03 μg/mL and the recovery was 90 %-105 % with the relative standard deviation (RSD) of no more than 7.0 % (n=11). The proposed method has been applied to the determination of boron in industrial silicon certified reference materials, and the results were consistent with the certified values.

About this research paper

What this paper is about

Trace boron in industrial silicon was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after the sample was decomposed with HNO3-HF mixed acid. The results showed that the volatilization of boron could be effectively inhibited by controlling the heating temperature at 140-180 ℃. The analytical spectral lines were investigated, and B 208.9 nm{161}was selected. Moreover, by properly deducting the background under the experimental conditions, the matrix and other coexiting elements had no interference with the spectra of B 208.9 nm{161}. Under the optimal working conditions of instrument, the detection limit of method was 0.03 μg/mL and the recovery was 90 %-105 % with the relative standard deviation (RSD) of no more than 7.0 % (n=11). The proposed method has been applied to the determination of boron in industrial silicon certified reference materials, and the results were consistent with the certified values.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Trace boron in industrial silicon was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after the sample was decomposed with HNO3-HF mixed acid. The results showed that the volatilization of boron could be effectively inhibited by controlling the heating temperature at 140-180 ℃. The analytical spectral lines were investigated, and B 208.9 nm{161}was selected. Moreover, by properly deducting the background under the experimental conditions, the matrix and other coexiting elements had no interference with the spectra of B 208.9 nm{161}. Under the optimal working conditions of instrument, the detection limit of method was 0.03 μg/mL and the recovery was 90 %-105 % with the relative standard deviation (RSD) of no more than 7.0 % (n=11). The proposed method has been applied to the determination of boron in industrial silicon certified reference materials, and the results were consistent with the certified values.

Key concepts: Boron, Analytical Chemistry (journal), Inductively coupled plasma, Detection limit, Silicon, Volatilisation, Inductively coupled plasma atomic emission spectroscopy, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace boron in industrial silicon by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens