Influence of central corneal thickness on intraocular pressure measured with three tonometers

Zhou He

Open publisher page 0 citations

Abstract

Objective To evaluate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)values measured with Icare rebound tonometer(Icare),Goldmann applanation tonometer(GAT)and PASCAL dynamic contour tonometer(DCT).Methods CCT and IOP were measured in 152 eyes of 78 cases.IOP measurement was performed on each eye with Icare,GAT and DCT.The IOP values with three tonometers under different CCT were compared,and the relations between IOP and CCT were analyzed.Results The mean IOP values measured with Icare,GAT and DCT were(19.16±5.03)mmHg(1 kPa=7.5 mmHg),(18.41±4.52)mmHg and(17.23±3.69)mmHg respectively.There was significant difference among Icare,GAT and DCT(F=7.256,P=0.001).IOP values detected with Icare and GAT had positive correlation with CCT(r=0.341,P0.001;r=0.333,P0.001).When CCT changed 10 μm,IOP of Icare changed 0.47 mmHg,the IOP of GAT changed 0.41 mmHg;While the correlation between IOP values of DCT and CCT was quite opposite(r=0.032,P=0.699).Conclusions The IOP values measured with Icare and GAT show a significant dependency on CCT,whereas Icare is more dependent on CCT than GAT.IOP values measured with DCT shows no significant dependency on CCT.

About this research paper

What this paper is about

Objective To evaluate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)values measured with Icare rebound tonometer(Icare),Goldmann applanation tonometer(GAT)and PASCAL dynamic contour tonometer(DCT).Methods CCT and IOP were measured in 152 eyes of 78 cases.IOP measurement was performed on each eye with Icare,GAT and DCT.The IOP values with three tonometers under different CCT were compared,and the relations between IOP and CCT were analyzed.Results The mean IOP values measured with Icare,GAT and DCT were(19.16±5.03)mmHg(1 kPa=7.5 mmHg),(18.41±4.52)mmHg and(17.23±3.69)mmHg respectively.There was significant difference among Icare,GAT and DCT(F=7.256,P=0.001).IOP values detected with Icare and GAT had positive correlation with CCT(r=0.341,P0.001;r=0.333,P0.001).When CCT changed 10 μm,IOP of Icare changed 0.47 mmHg,the IOP of GAT changed 0.41 mmHg;While the correlation between IOP values of DCT and CCT was quite opposite(r=0.032,P=0.699).Conclusions The IOP values measured with Icare and GAT show a significant dependency on CCT,whereas Icare is more dependent on CCT than GAT.IOP values measured with DCT shows no significant dependency on CCT.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)values measured with Icare rebound tonometer(Icare),Goldmann applanation tonometer(GAT)and PASCAL dynamic contour tonometer(DCT).Methods CCT and IOP were measured in 152 eyes of 78 cases.IOP measurement was performed on each eye with Icare,GAT and DCT.The IOP values with three tonometers under different CCT were compared,and the relations between IOP and CCT were analyzed.Results The mean IOP values measured with Icare,GAT and DCT were(19.16±5.03)mmHg(1 kPa=7.5 mmHg),(18.41±4.52)mmHg and(17.23±3.69)mmHg respectively.There was significant difference among Icare,GAT and DCT(F=7.256,P=0.001).IOP values detected with Icare and GAT had positive correlation with CCT(r=0.341,P0.001;r=0.333,P0.001).When CCT changed 10 μm,IOP of Icare changed 0.47 mmHg,the IOP of GAT changed 0.41 mmHg;While the correlation between IOP values of DCT and CCT was quite opposite(r=0.032,P=0.699).Conclusions The IOP values measured with Icare and GAT show a significant dependency on CCT,whereas Icare is more dependent on CCT than GAT.IOP values measured with DCT shows no significant dependency on CCT.

Key concepts: Goldmann Applanation Tonometer, Intraocular pressure, Ophthalmology, Medicine, Significant difference, Positive correlation, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of central corneal thickness on intraocular pressure measured with three tonometers — Research Paper | ScholarLens