2012•Chinese Journal of Analysis LaboratoryRequires access

Determination of imidacloprid,acetamiprid,carbendazim and thiophanate-methyl residues in tobacco by high performance liquid chromatography

Hongcheng Liu

Open publisher page 0 citations

Abstract

A method for the determination of imidacloprid,acetamiprid,carbendazim and thiophanate-methyl residues in tobacco by high performance liquid chromatography with DAD detector was established.Tobacco samples were extracted with acetonitrile and cleaned up with a PSA SPE column,then separated in a gradient elution mode.The results showed that the average recoveries of 4 pesticides were in the range of 82.0%~112.4% and the relative standard deviations were 2.0%~5.3%.The method is simple,accurate,reproducible and has good cleanup effect.

About this research paper

What this paper is about

A method for the determination of imidacloprid,acetamiprid,carbendazim and thiophanate-methyl residues in tobacco by high performance liquid chromatography with DAD detector was established.Tobacco samples were extracted with acetonitrile and cleaned up with a PSA SPE column,then separated in a gradient elution mode.The results showed that the average recoveries of 4 pesticides were in the range of 82.0%~112.4% and the relative standard deviations were 2.0%~5.3%.The method is simple,accurate,reproducible and has good cleanup effect.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of imidacloprid,acetamiprid,carbendazim and thiophanate-methyl residues in tobacco by high performance liquid chromatography with DAD detector was established.Tobacco samples were extracted with acetonitrile and cleaned up with a PSA SPE column,then separated in a gradient elution mode.The results showed that the average recoveries of 4 pesticides were in the range of 82.0%~112.4% and the relative standard deviations were 2.0%~5.3%.The method is simple,accurate,reproducible and has good cleanup effect.

Key concepts: Chemistry, Acetamiprid, Chromatography, Carbendazim, Imidacloprid, Detection limit, Acetonitrile, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of imidacloprid,acetamiprid,carbendazim and thiophanate-methyl residues in tobacco by high performance liquid chromatography — Research Paper | ScholarLens