2008•Linchuang huicuiRequires access

Role of intravascular ultrasound in drug-eluting stent implantation

Yuming Li

Open publisher page 0 citations

Abstract

Objective To evaluate the role of intravascular ultrasound(IVUS) in drug-eluting stent(DES) implantation.Methods A total of 251 patients with DES were divided into two groups.In group Ⅰ(n=146),DES were implanted by coronary angiography(CAG) only;group Ⅱ(n=115),IVUS was used to evaluate the lesions and the effects.Results In group Ⅱ,61 DES(53.0%) were optimum by CAG,but did not achieve the criteria of IVUS,additional higher-pressure post-dilatation was necessary.After that,the difference in the highest dilation pressure(14.27±1.14) atm vs(18.62±0.63) atm(P0.01),the stent symmetric index(13.9±1.5) % vs(4.1±1.2) %(P0.01),the stent inflation index(76.0±3.4) % vs(95.2±4.2) %(P0.01) were obvious.Between the two groups,there was obvious difference in stent diameter(2.97±0.41) mm vs(3.45±0.32) mm(P0.01),stent-length(21.00±3.23) mm vs(25.00±4.17) mm(P0.01),and the highest pressure of dilatation(14.23±1.25) atm vs(18.62±0.63) atm(P0.01).Conclusion IVUS is valuble in guiding DES implantation.

About this research paper

What this paper is about

Objective To evaluate the role of intravascular ultrasound(IVUS) in drug-eluting stent(DES) implantation.Methods A total of 251 patients with DES were divided into two groups.In group Ⅰ(n=146),DES were implanted by coronary angiography(CAG) only;group Ⅱ(n=115),IVUS was used to evaluate the lesions and the effects.Results In group Ⅱ,61 DES(53.0%) were optimum by CAG,but did not achieve the criteria of IVUS,additional higher-pressure post-dilatation was necessary.After that,the difference in the highest dilation pressure(14.27±1.14) atm vs(18.62±0.63) atm(P0.01),the stent symmetric index(13.9±1.5) % vs(4.1±1.2) %(P0.01),the stent inflation index(76.0±3.4) % vs(95.2±4.2) %(P0.01) were obvious.Between the two groups,there was obvious difference in stent diameter(2.97±0.41) mm vs(3.45±0.32) mm(P0.01),stent-length(21.00±3.23) mm vs(25.00±4.17) mm(P0.01),and the highest pressure of dilatation(14.23±1.25) atm vs(18.62±0.63) atm(P0.01).Conclusion IVUS is valuble in guiding DES implantation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the role of intravascular ultrasound(IVUS) in drug-eluting stent(DES) implantation.Methods A total of 251 patients with DES were divided into two groups.In group Ⅰ(n=146),DES were implanted by coronary angiography(CAG) only;group Ⅱ(n=115),IVUS was used to evaluate the lesions and the effects.Results In group Ⅱ,61 DES(53.0%) were optimum by CAG,but did not achieve the criteria of IVUS,additional higher-pressure post-dilatation was necessary.After that,the difference in the highest dilation pressure(14.27±1.14) atm vs(18.62±0.63) atm(P0.01),the stent symmetric index(13.9±1.5) % vs(4.1±1.2) %(P0.01),the stent inflation index(76.0±3.4) % vs(95.2±4.2) %(P0.01) were obvious.Between the two groups,there was obvious difference in stent diameter(2.97±0.41) mm vs(3.45±0.32) mm(P0.01),stent-length(21.00±3.23) mm vs(25.00±4.17) mm(P0.01),and the highest pressure of dilatation(14.23±1.25) atm vs(18.62±0.63) atm(P0.01).Conclusion IVUS is valuble in guiding DES implantation.

Key concepts: Intravascular ultrasound, Medicine, Stent, Coronary angiography, Drug-eluting stent, Cardiology, Angiography, Nuclear medicine