2004•Amino Acids & Biotic ResourcesRequires access

Determination of Aromatic Amino Acids by HPLC with UV Detection at Changeable Wavelength

Gong Aijun

Open publisher page 1 citations

Abstract

A method for determination of aromatic amino acids by RP-HPLC with UV detection at changeable wavelength was developed . Chromatographic conditions were as follows: mobile phase of phosphate buffer (pH6.0) and methanol in a ratio of 70: 30; flow rate of 0.6 ml/min. Samples were finally analyzed in 10min. Linear range of tyrosine, phenylalanine and tryptophane was 50-500μg·mL -1 , 200-20000μg·mL -1 and 20-2000μg·mL -1 . Their detection limit was 10μg·mL -1 、150μg·mL -1 and 5μg·mL -1 .

About this research paper

What this paper is about

A method for determination of aromatic amino acids by RP-HPLC with UV detection at changeable wavelength was developed . Chromatographic conditions were as follows: mobile phase of phosphate buffer (pH6.0) and methanol in a ratio of 70: 30; flow rate of 0.6 ml/min. Samples were finally analyzed in 10min. Linear range of tyrosine, phenylalanine and tryptophane was 50-500μg·mL -1 , 200-20000μg·mL -1 and 20-2000μg·mL -1 . Their detection limit was 10μg·mL -1 、150μg·mL -1 and 5μg·mL -1 .

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of aromatic amino acids by RP-HPLC with UV detection at changeable wavelength was developed . Chromatographic conditions were as follows: mobile phase of phosphate buffer (pH6.0) and methanol in a ratio of 70: 30; flow rate of 0.6 ml/min. Samples were finally analyzed in 10min. Linear range of tyrosine, phenylalanine and tryptophane was 50-500μg·mL -1 , 200-20000μg·mL -1 and 20-2000μg·mL -1 . Their detection limit was 10μg·mL -1 、150μg·mL -1 and 5μg·mL -1 .

Key concepts: Chromatography, Phenylalanine, High-performance liquid chromatography, Detection limit, Chemistry, Linear range, Aromatic amino acids, Amino acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Aromatic Amino Acids by HPLC with UV Detection at Changeable Wavelength — Research Paper | ScholarLens