Objective:Establish graphite furnace atomic absorption spectrometry urine test methods of iron.Methods: Directly poured the diluted urine sample into graphite furnace,join ascorbic acid as a matrix modifier,dry,grey,and determinated atoms with spectrometry after compared with the standard work curve.Results: There was good linear correlation at 0 μg/L to 500 μg/L and r=0.9949-0.9993.the detect limit is 20 μg/L,the sample RSD is 2.5%~21.9%,and the recovery rate is in the range of 93.2%~103.7%.Conclusion: Samples only needed simple dilution.The method was simple,fast,highly sensitive and reproducible with good linear correlation of work curve and good recovery rate.The application of it would get satisfactory results.

About this research paper

What this paper is about

Objective:Establish graphite furnace atomic absorption spectrometry urine test methods of iron.Methods: Directly poured the diluted urine sample into graphite furnace,join ascorbic acid as a matrix modifier,dry,grey,and determinated atoms with spectrometry after compared with the standard work curve.Results: There was good linear correlation at 0 μg/L to 500 μg/L and r=0.9949-0.9993.the detect limit is 20 μg/L,the sample RSD is 2.5%~21.9%,and the recovery rate is in the range of 93.2%~103.7%.Conclusion: Samples only needed simple dilution.The method was simple,fast,highly sensitive and reproducible with good linear correlation of work curve and good recovery rate.The application of it would get satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:Establish graphite furnace atomic absorption spectrometry urine test methods of iron.Methods: Directly poured the diluted urine sample into graphite furnace,join ascorbic acid as a matrix modifier,dry,grey,and determinated atoms with spectrometry after compared with the standard work curve.Results: There was good linear correlation at 0 μg/L to 500 μg/L and r=0.9949-0.9993.the detect limit is 20 μg/L,the sample RSD is 2.5%~21.9%,and the recovery rate is in the range of 93.2%~103.7%.Conclusion: Samples only needed simple dilution.The method was simple,fast,highly sensitive and reproducible with good linear correlation of work curve and good recovery rate.The application of it would get satisfactory results.

Key concepts: Graphite furnace atomic absorption, Graphite, Chemistry, Analytical Chemistry (journal), Dilution, Mass spectrometry, Ascorbic acid, Standard curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of urine iron with graphite tube atomic absorption spectrometry — Research Paper | ScholarLens