2007Shipin yu yaopinRequires access

Determination of Baicalin in Niuhuang Pills by HPLC

Shi Xiao

Open publisher page 0 citations

Abstract

Objective To establish a HPLC method for the determination of baicalin in Niuhuang pills. Methods A HPLC method was performed on a Kromasasil C18 column(150 mm×4. 6 mm)with a mobile phase consisting of methanol - water -phosphoric aci(d47:53:0.2). The detection wavelength was set at 280 nm. Results The linear range of baicalin was 0.17 ̄1.12μg ( r = 0. 999 9) . The average recovery of baicalin was 98.30 (%n =6)with RSD of 1.37%. Conclusion This method is accurate , reliable and reproducible. It can be used for theassaying of baicalin in Niuhuang pills.

About this research paper

What this paper is about

Objective To establish a HPLC method for the determination of baicalin in Niuhuang pills. Methods A HPLC method was performed on a Kromasasil C18 column(150 mm×4. 6 mm)with a mobile phase consisting of methanol - water -phosphoric aci(d47:53:0.2). The detection wavelength was set at 280 nm. Results The linear range of baicalin was 0.17 ̄1.12μg ( r = 0. 999 9) . The average recovery of baicalin was 98.30 (%n =6)with RSD of 1.37%. Conclusion This method is accurate , reliable and reproducible. It can be used for theassaying of baicalin in Niuhuang pills.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a HPLC method for the determination of baicalin in Niuhuang pills. Methods A HPLC method was performed on a Kromasasil C18 column(150 mm×4. 6 mm)with a mobile phase consisting of methanol - water -phosphoric aci(d47:53:0.2). The detection wavelength was set at 280 nm. Results The linear range of baicalin was 0.17 ̄1.12μg ( r = 0. 999 9) . The average recovery of baicalin was 98.30 (%n =6)with RSD of 1.37%. Conclusion This method is accurate , reliable and reproducible. It can be used for theassaying of baicalin in Niuhuang pills.

Key concepts: Baicalin, High-performance liquid chromatography, Chromatography, Chemistry, Phosphoric acid, Linear range, Pill, Pharmacology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Baicalin in Niuhuang Pills by HPLC — Research Paper | ScholarLens