2014Laboratory MedicineRequires access

The investigation on the internal quality control of HBV DNA determination by fluorescence quantitation PCR

Jiang Lingl

Open publisher page 0 citations

Abstract

Objective To investigate the internal quality control of hepatitis B virus( HBV) DNA determination by real time fluorescence quantitation polymerase chain reaction( PCR). Methods The coefficients of variation( CV) of previous 20 internal quality control data of HBV DNA determination under routine condition from PCR laboratories in Shanghai region were analyzed,and the control chart was drawn by the mean( x珋± s). 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method were used to determine internal quality control data from laboratory A,B and C whose CV were ≥ 10%,5%- 10% and 1%- 5%,respectively. Results When the concentrations of the internal quality control materials were 5 × 104and 5 × 106IU /mL,there were no error data detected in laboratory A whose CV were 14. 96% and 12. 15% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. There were both 2 random error data detected in laboratory B whose CV were 6. 49% and 5. 00% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. The CV of laboratory C were 4. 36% and 2. 43%. There were 3 systematic error data detected by13s/22smulti-rule quality control method,and there were no error data detected by Levey-Jennings single-rule quality control method. Conclusions When the CV of the previous 20 internal quality control data were ≥ 10%,the error detections are all low both by the multi-rule quality control method and single-rule quality control method. The laboratory should set the suitable CV and use the multi-rule quality control method to improve the systematic error detection.

About this research paper

What this paper is about

Objective To investigate the internal quality control of hepatitis B virus( HBV) DNA determination by real time fluorescence quantitation polymerase chain reaction( PCR). Methods The coefficients of variation( CV) of previous 20 internal quality control data of HBV DNA determination under routine condition from PCR laboratories in Shanghai region were analyzed,and the control chart was drawn by the mean( x珋± s). 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method were used to determine internal quality control data from laboratory A,B and C whose CV were ≥ 10%,5%- 10% and 1%- 5%,respectively. Results When the concentrations of the internal quality control materials were 5 × 104and 5 × 106IU /mL,there were no error data detected in laboratory A whose CV were 14. 96% and 12. 15% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. There were both 2 random error data detected in laboratory B whose CV were 6. 49% and 5. 00% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. The CV of laboratory C were 4. 36% and 2. 43%. There were 3 systematic error data detected by13s/22smulti-rule quality control method,and there were no error data detected by Levey-Jennings single-rule quality control method. Conclusions When the CV of the previous 20 internal quality control data were ≥ 10%,the error detections are all low both by the multi-rule quality control method and single-rule quality control method. The laboratory should set the suitable CV and use the multi-rule quality control method to improve the systematic error detection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the internal quality control of hepatitis B virus( HBV) DNA determination by real time fluorescence quantitation polymerase chain reaction( PCR). Methods The coefficients of variation( CV) of previous 20 internal quality control data of HBV DNA determination under routine condition from PCR laboratories in Shanghai region were analyzed,and the control chart was drawn by the mean( x珋± s). 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method were used to determine internal quality control data from laboratory A,B and C whose CV were ≥ 10%,5%- 10% and 1%- 5%,respectively. Results When the concentrations of the internal quality control materials were 5 × 104and 5 × 106IU /mL,there were no error data detected in laboratory A whose CV were 14. 96% and 12. 15% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. There were both 2 random error data detected in laboratory B whose CV were 6. 49% and 5. 00% by 13s/22smulti-rule quality control method and Levey-Jennings single-rule quality control method,respectively. The CV of laboratory C were 4. 36% and 2. 43%. There were 3 systematic error data detected by13s/22smulti-rule quality control method,and there were no error data detected by Levey-Jennings single-rule quality control method. Conclusions When the CV of the previous 20 internal quality control data were ≥ 10%,the error detections are all low both by the multi-rule quality control method and single-rule quality control method. The laboratory should set the suitable CV and use the multi-rule quality control method to improve the systematic error detection.

Key concepts: Quality (philosophy), Control chart, Control (management), Polymerase chain reaction, Computer science, Statistics, Biology, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
The investigation on the internal quality control of HBV DNA determination by fluorescence quantitation PCR — Research Paper | ScholarLens