2008•Modern AgrochemicalsRequires access

Determination of Quick-Penteration Cypermethrin 2.5% EC by Gas Chromatograph

Yu‐Qing Liu

Open publisher page 0 citations

Abstract

A method for the determination of laurocapram and cypermethrin 2.5% EC by GC with 5% OV-101 column using Dicyclohexyl phthalate as internal standard was developed.The standard deviation for laurocapram and cypermethrin were 0.049 6 and 0.058 3.The coefficient of variation for laurocapram and cypermethrin were 4.82% and 2.29%.The recovery for laurocapram ranged between 98.58% and 101.52%,and the recovery for cypermethrin ranged between 98.65% and 104.90%.The method is convenient,rapid and accuracy.

About this research paper

What this paper is about

A method for the determination of laurocapram and cypermethrin 2.5% EC by GC with 5% OV-101 column using Dicyclohexyl phthalate as internal standard was developed.The standard deviation for laurocapram and cypermethrin were 0.049 6 and 0.058 3.The coefficient of variation for laurocapram and cypermethrin were 4.82% and 2.29%.The recovery for laurocapram ranged between 98.58% and 101.52%,and the recovery for cypermethrin ranged between 98.65% and 104.90%.The method is convenient,rapid and accuracy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of laurocapram and cypermethrin 2.5% EC by GC with 5% OV-101 column using Dicyclohexyl phthalate as internal standard was developed.The standard deviation for laurocapram and cypermethrin were 0.049 6 and 0.058 3.The coefficient of variation for laurocapram and cypermethrin were 4.82% and 2.29%.The recovery for laurocapram ranged between 98.58% and 101.52%,and the recovery for cypermethrin ranged between 98.65% and 104.90%.The method is convenient,rapid and accuracy.

Key concepts: Cypermethrin, Chromatography, Coefficient of variation, Gas chromatography, Chemistry, Phthalate, Relative standard deviation, Toxicology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Quick-Penteration Cypermethrin 2.5% EC by Gas Chromatograph — Research Paper | ScholarLens