2014Shipin anquan zhiliang jiance xuebaoRequires access

Determination of cypermethrin pesticide in lettuce

Shi Shao

Open publisher page 0 citations

Abstract

Objective To establish a method for determination of cypermethrin pesticide in lettuce. Methods Samples were extracted with acetonitrile, purified by Agilent SPE, Florisil column, NH2 column and C18 column, respectively, and detected by capillary column gas chromatography with ECD as detector. Results Recoveries of cypermethrin were 91.21%~102.78% with coefficient of variation of 0.63%~3.57%. The lowest detection limit was 0.001 mg·kg-1. Conclusion The method is simple, sensitive, accurate and reproducible, and the separation of cypermethrin cis-cypermethrin and trans-cypermethrin 2:3 bimodal peak is very satisfactory. This method can be used to detect residues of cypermethrin in lettuce.

About this research paper

What this paper is about

Objective To establish a method for determination of cypermethrin pesticide in lettuce. Methods Samples were extracted with acetonitrile, purified by Agilent SPE, Florisil column, NH2 column and C18 column, respectively, and detected by capillary column gas chromatography with ECD as detector. Results Recoveries of cypermethrin were 91.21%~102.78% with coefficient of variation of 0.63%~3.57%. The lowest detection limit was 0.001 mg·kg-1. Conclusion The method is simple, sensitive, accurate and reproducible, and the separation of cypermethrin cis-cypermethrin and trans-cypermethrin 2:3 bimodal peak is very satisfactory. This method can be used to detect residues of cypermethrin in lettuce.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determination of cypermethrin pesticide in lettuce. Methods Samples were extracted with acetonitrile, purified by Agilent SPE, Florisil column, NH2 column and C18 column, respectively, and detected by capillary column gas chromatography with ECD as detector. Results Recoveries of cypermethrin were 91.21%~102.78% with coefficient of variation of 0.63%~3.57%. The lowest detection limit was 0.001 mg·kg-1. Conclusion The method is simple, sensitive, accurate and reproducible, and the separation of cypermethrin cis-cypermethrin and trans-cypermethrin 2:3 bimodal peak is very satisfactory. This method can be used to detect residues of cypermethrin in lettuce.

Key concepts: Cypermethrin, Chromatography, Chemistry, Detection limit, Pesticide, Pesticide residue, Coefficient of variation, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of cypermethrin pesticide in lettuce — Research Paper | ScholarLens