1999•China Nuclear Science and Technology ReportRequires access

Risk assessment of accident of uncontrolled boron dilution at shutdown condition for PWR

Ke Guotu, Xu Hanming

Open publisher page 0 citations

Abstract

Taking Guangdong Daya Bay Nuclear Power Station for reference plant, the potential accident initiators of uncontrolled boron dilution at shutdown condition for pressurized water reactor is analyzed and classified systematically. Based upon French NPPs operating experience over 750 reactor-years, the PSA method is adopted to evaluate the risk related to such accident. Finally, according to the estimated result some appropriate measures and recommendations to reduce the corresponding risk are proposed.

About this research paper

What this paper is about

Taking Guangdong Daya Bay Nuclear Power Station for reference plant, the potential accident initiators of uncontrolled boron dilution at shutdown condition for pressurized water reactor is analyzed and classified systematically. Based upon French NPPs operating experience over 750 reactor-years, the PSA method is adopted to evaluate the risk related to such accident. Finally, according to the estimated result some appropriate measures and recommendations to reduce the corresponding risk are proposed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Taking Guangdong Daya Bay Nuclear Power Station for reference plant, the potential accident initiators of uncontrolled boron dilution at shutdown condition for pressurized water reactor is analyzed and classified systematically. Based upon French NPPs operating experience over 750 reactor-years, the PSA method is adopted to evaluate the risk related to such accident. Finally, according to the estimated result some appropriate measures and recommendations to reduce the corresponding risk are proposed.

Key concepts: Shutdown, Pressurized water reactor, Nuclear engineering, Environmental science, Nuclear power plant, Nuclear power, Dilution, Boron

Related papers

Back to paper searchBrowse research topicsOriginal source
Risk assessment of accident of uncontrolled boron dilution at shutdown condition for PWR — Research Paper | ScholarLens