2010•Chronic Pathematology JournalRequires access

Determination of the Contents of Atropine Sulfate Injection by HPLC

Deng Xue-yin

Open publisher page 0 citations

Abstract

Objective To develop a HPLC internal standard method for determination of Atropine Sulfate Injection.Methods The C18 column (4.6 mm× 250 mm,5 μm)was used,acetonitrile-water-triethylamine (25:75:0.1,V /V) was used as mobile phase,flow rate:1.0 ml/min,The UV detection wavelength is 210 nm,Phenacetin Was selected as internal standard.Results The inearity was obtained from 40 to 200 μg/ml of Atropine Sulfate Injection(r =0.997 8,The average recoveries for Atropine Sulfate were 101.2%,97.6% and 102.3%,The RSD were less than 5%).Conclusion The method is simple,accurate and reliable and can be used for quality control of atropine sulfate injection.

About this research paper

What this paper is about

Objective To develop a HPLC internal standard method for determination of Atropine Sulfate Injection.Methods The C18 column (4.6 mm× 250 mm,5 μm)was used,acetonitrile-water-triethylamine (25:75:0.1,V /V) was used as mobile phase,flow rate:1.0 ml/min,The UV detection wavelength is 210 nm,Phenacetin Was selected as internal standard.Results The inearity was obtained from 40 to 200 μg/ml of Atropine Sulfate Injection(r =0.997 8,The average recoveries for Atropine Sulfate were 101.2%,97.6% and 102.3%,The RSD were less than 5%).Conclusion The method is simple,accurate and reliable and can be used for quality control of atropine sulfate injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a HPLC internal standard method for determination of Atropine Sulfate Injection.Methods The C18 column (4.6 mm× 250 mm,5 μm)was used,acetonitrile-water-triethylamine (25:75:0.1,V /V) was used as mobile phase,flow rate:1.0 ml/min,The UV detection wavelength is 210 nm,Phenacetin Was selected as internal standard.Results The inearity was obtained from 40 to 200 μg/ml of Atropine Sulfate Injection(r =0.997 8,The average recoveries for Atropine Sulfate were 101.2%,97.6% and 102.3%,The RSD were less than 5%).Conclusion The method is simple,accurate and reliable and can be used for quality control of atropine sulfate injection.

Key concepts: Atropine sulfate, Chromatography, Atropine, Triethylamine, Medicine, High-performance liquid chromatography, Sulfate, Phenacetin