2008Journal of Analytical ScienceRequires access

Fast Analysis of Inorganic Anions by Ion-interaction Chromatography Using a Monolithic Column

Hongjing Ai

Open publisher page 1 citations

Abstract

An investigation on fast analysis of inorganic anions by ion-interaction chromatography using a silica-based monolithic column and direct conductivity detection was carried out.Tetrabutylammonium hydroxide(TBA-OH)-phthalic acid was used as an eluent.The effects of eluent concentration,eluent pH and flow rate on anions retention time were discussed.When the eluent flow rate was 6 mL/min,using 1.5 mmol/L TBA-OH and 1.1 mmol/L phthalic acid as the eluent(pH 5.5),excellent simultaneous separation and determination of seven inorganic anions (Cl-,NO-2,Br-,NO-3,ClO-3,SO2-4 and I-) were achieved just in 1 min.Detection limits(S/N=3) for inorganic anions were obtained in the range of 0.3~1.9 mg/L.Relative standard deviations based on chromatographic peak areas and peak heights were 0.4%~2.2% and 0.1%~1.5%(n=5),respectively.The method has been applied to the determination of inorganic anions in mineralized water and groundwater with satisfactory results.Recoveries of inorganic anions after spiking were 97.9%~100.3%.

About this research paper

What this paper is about

An investigation on fast analysis of inorganic anions by ion-interaction chromatography using a silica-based monolithic column and direct conductivity detection was carried out.Tetrabutylammonium hydroxide(TBA-OH)-phthalic acid was used as an eluent.The effects of eluent concentration,eluent pH and flow rate on anions retention time were discussed.When the eluent flow rate was 6 mL/min,using 1.5 mmol/L TBA-OH and 1.1 mmol/L phthalic acid as the eluent(pH 5.5),excellent simultaneous separation and determination of seven inorganic anions (Cl-,NO-2,Br-,NO-3,ClO-3,SO2-4 and I-) were achieved just in 1 min.Detection limits(S/N=3) for inorganic anions were obtained in the range of 0.3~1.9 mg/L.Relative standard deviations based on chromatographic peak areas and peak heights were 0.4%~2.2% and 0.1%~1.5%(n=5),respectively.The method has been applied to the determination of inorganic anions in mineralized water and groundwater with satisfactory results.Recoveries of inorganic anions after spiking were 97.9%~100.3%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An investigation on fast analysis of inorganic anions by ion-interaction chromatography using a silica-based monolithic column and direct conductivity detection was carried out.Tetrabutylammonium hydroxide(TBA-OH)-phthalic acid was used as an eluent.The effects of eluent concentration,eluent pH and flow rate on anions retention time were discussed.When the eluent flow rate was 6 mL/min,using 1.5 mmol/L TBA-OH and 1.1 mmol/L phthalic acid as the eluent(pH 5.5),excellent simultaneous separation and determination of seven inorganic anions (Cl-,NO-2,Br-,NO-3,ClO-3,SO2-4 and I-) were achieved just in 1 min.Detection limits(S/N=3) for inorganic anions were obtained in the range of 0.3~1.9 mg/L.Relative standard deviations based on chromatographic peak areas and peak heights were 0.4%~2.2% and 0.1%~1.5%(n=5),respectively.The method has been applied to the determination of inorganic anions in mineralized water and groundwater with satisfactory results.Recoveries of inorganic anions after spiking were 97.9%~100.3%.

Key concepts: Column chromatography, Chemistry, Ion chromatography, Phthalic acid, Detection limit, Chromatography, Tetrabutylammonium hydroxide, Hydroxide

Related papers

Back to paper searchBrowse research topicsOriginal source
Fast Analysis of Inorganic Anions by Ion-interaction Chromatography Using a Monolithic Column — Research Paper | ScholarLens