Fast Analysis of Inorganic Anions by Ion-interaction Chromatography Using a Monolithic Column
Hongjing Ai
Abstract
Hongjing Ai
Abstract
An investigation on fast analysis of inorganic anions by ion-interaction chromatography using a silica-based monolithic column and direct conductivity detection was carried out.Tetrabutylammonium hydroxide(TBA-OH)-phthalic acid was used as an eluent.The effects of eluent concentration,eluent pH and flow rate on anions retention time were discussed.When the eluent flow rate was 6 mL/min,using 1.5 mmol/L TBA-OH and 1.1 mmol/L phthalic acid as the eluent(pH 5.5),excellent simultaneous separation and determination of seven inorganic anions (Cl-,NO-2,Br-,NO-3,ClO-3,SO2-4 and I-) were achieved just in 1 min.Detection limits(S/N=3) for inorganic anions were obtained in the range of 0.3~1.9 mg/L.Relative standard deviations based on chromatographic peak areas and peak heights were 0.4%~2.2% and 0.1%~1.5%(n=5),respectively.The method has been applied to the determination of inorganic anions in mineralized water and groundwater with satisfactory results.Recoveries of inorganic anions after spiking were 97.9%~100.3%.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An investigation on fast analysis of inorganic anions by ion-interaction chromatography using a silica-based monolithic column and direct conductivity detection was carried out.Tetrabutylammonium hydroxide(TBA-OH)-phthalic acid was used as an eluent.The effects of eluent concentration,eluent pH and flow rate on anions retention time were discussed.When the eluent flow rate was 6 mL/min,using 1.5 mmol/L TBA-OH and 1.1 mmol/L phthalic acid as the eluent(pH 5.5),excellent simultaneous separation and determination of seven inorganic anions (Cl-,NO-2,Br-,NO-3,ClO-3,SO2-4 and I-) were achieved just in 1 min.Detection limits(S/N=3) for inorganic anions were obtained in the range of 0.3~1.9 mg/L.Relative standard deviations based on chromatographic peak areas and peak heights were 0.4%~2.2% and 0.1%~1.5%(n=5),respectively.The method has been applied to the determination of inorganic anions in mineralized water and groundwater with satisfactory results.Recoveries of inorganic anions after spiking were 97.9%~100.3%.
Key concepts: Column chromatography, Chemistry, Ion chromatography, Phthalic acid, Detection limit, Chromatography, Tetrabutylammonium hydroxide, Hydroxide