2006•Journal of Hebei UniversityRequires access

Ion-selective Electrode Method by Preactivating in Sulfuric Acid for the Determination of Trace Fluoride

Qibin Chen

Open publisher page 0 citations

Abstract

An ion-selective eiectrode method was developed for the determination of the fluoride concentration at mg/L level.Fluoride ISE was preactivated in 0.5 mol/L H-2SO-4 medium and then fluoride was determined in TISAM medium.The linear range for the determination of fluoride is between 1.00 ×10~(-2)~1.00 ×10~(-7) mol/L,and the detection limit of the method is 1.9 μg/L.The method has been used for the determination of trace fluoride in tea drink,drinking water and milk with satisfactory results.A possible mechanism for the activation of FISE was proposed.

About this research paper

What this paper is about

An ion-selective eiectrode method was developed for the determination of the fluoride concentration at mg/L level.Fluoride ISE was preactivated in 0.5 mol/L H-2SO-4 medium and then fluoride was determined in TISAM medium.The linear range for the determination of fluoride is between 1.00 ×10~(-2)~1.00 ×10~(-7) mol/L,and the detection limit of the method is 1.9 μg/L.The method has been used for the determination of trace fluoride in tea drink,drinking water and milk with satisfactory results.A possible mechanism for the activation of FISE was proposed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ion-selective eiectrode method was developed for the determination of the fluoride concentration at mg/L level.Fluoride ISE was preactivated in 0.5 mol/L H-2SO-4 medium and then fluoride was determined in TISAM medium.The linear range for the determination of fluoride is between 1.00 ×10~(-2)~1.00 ×10~(-7) mol/L,and the detection limit of the method is 1.9 μg/L.The method has been used for the determination of trace fluoride in tea drink,drinking water and milk with satisfactory results.A possible mechanism for the activation of FISE was proposed.

Key concepts: Fluoride, Sulfuric acid, Chemistry, Detection limit, Ion selective electrode, Ion, Inorganic chemistry, Electrode

Related papers

Back to paper searchBrowse research topicsOriginal source
Ion-selective Electrode Method by Preactivating in Sulfuric Acid for the Determination of Trace Fluoride — Research Paper | ScholarLens