2010•Chinese Journal of Breast DiseaseRequires access

Ultrasound-guided Mammotome system in diagnosis and treatment of breast lesions:a report of 1761 cases

Zhang Ai-ling

Open publisher page 0 citations

Abstract

Objective To investigate the applicable value of ultrasound-guided Mammotome system in diagnosis and treatment of breast lesions.Methods From September 2007 to October 2008, 3665 breast lesions of 1761 patients were managed using ultrasound-guided Mammotome system for diagnosis and treatment in our department. The diagnostic and therapeutic results were evaluated in light with pathological examination and follow-up, and the experience was summed up.Results All the breast lesions were resected safely and completely. The diameter of the lesions was 0.5-2.3 cm. The mean operative time was 15 min (5-25 min). The length of incision was 3-5 mm. The average blood loss was 8 ml. No severer complications were found.Conclusion Excision of breast lesions using ultrasound guided Mammotome system is of minimal invasion, easy operation, short time and satisfactory cosmetic effect. It is safe and feasible.

About this research paper

What this paper is about

Objective To investigate the applicable value of ultrasound-guided Mammotome system in diagnosis and treatment of breast lesions.Methods From September 2007 to October 2008, 3665 breast lesions of 1761 patients were managed using ultrasound-guided Mammotome system for diagnosis and treatment in our department. The diagnostic and therapeutic results were evaluated in light with pathological examination and follow-up, and the experience was summed up.Results All the breast lesions were resected safely and completely. The diameter of the lesions was 0.5-2.3 cm. The mean operative time was 15 min (5-25 min). The length of incision was 3-5 mm. The average blood loss was 8 ml. No severer complications were found.Conclusion Excision of breast lesions using ultrasound guided Mammotome system is of minimal invasion, easy operation, short time and satisfactory cosmetic effect. It is safe and feasible.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the applicable value of ultrasound-guided Mammotome system in diagnosis and treatment of breast lesions.Methods From September 2007 to October 2008, 3665 breast lesions of 1761 patients were managed using ultrasound-guided Mammotome system for diagnosis and treatment in our department. The diagnostic and therapeutic results were evaluated in light with pathological examination and follow-up, and the experience was summed up.Results All the breast lesions were resected safely and completely. The diameter of the lesions was 0.5-2.3 cm. The mean operative time was 15 min (5-25 min). The length of incision was 3-5 mm. The average blood loss was 8 ml. No severer complications were found.Conclusion Excision of breast lesions using ultrasound guided Mammotome system is of minimal invasion, easy operation, short time and satisfactory cosmetic effect. It is safe and feasible.

Key concepts: Mammotome, Medicine, Ultrasound, Pathological, Radiology, Surgery, Breast cancer, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasound-guided Mammotome system in diagnosis and treatment of breast lesions:a report of 1761 cases — Research Paper | ScholarLens