Determination of D-Cyphenothrin and Propoxur 10% EC by GC
Cheng Yun-bin
Abstract
Cheng Yun-bin
Abstract
This dissertation reported a specific quantitative analysis method for D-cyphenothrin and propoxur 10%EC by GC.The sample was separated in a column packed with 5%OV-101 using di-n-amyl-o-phthalate as internal standard and detected by flame ionization detector.The reults showed that the standard deviation for D-cyphenothrin and propoxur were 0.054 and 0.078,the coefficient of variation were 0.98 and 1.46%,the recoveries were between 99.12-100.72%and 99.06-101.25%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This dissertation reported a specific quantitative analysis method for D-cyphenothrin and propoxur 10%EC by GC.The sample was separated in a column packed with 5%OV-101 using di-n-amyl-o-phthalate as internal standard and detected by flame ionization detector.The reults showed that the standard deviation for D-cyphenothrin and propoxur were 0.054 and 0.078,the coefficient of variation were 0.98 and 1.46%,the recoveries were between 99.12-100.72%and 99.06-101.25%.
Key concepts: Propoxur, Chromatography, Coefficient of variation, Flame ionization detector, Phthalate, Relative standard deviation, Chemistry, Gas chromatography